FIG. 5: Vacuum cutoff valve removal and cleaning
Clean vacuum ball float valve (Fig. 5). Empty recovery
tank, then open recovery tank lid. Grasp valve assembly
and pull gently toward the front of the unit, taking care
not to distort the strainer screen. Rinse assembly clean
and make sure float ball moves freely inside assembly.
Clean recovery tank strainer (Fig. 6, pumpout models
only). Remove strainer by gently rotating it and lifting
upward. Rinse filter clean with water and reinstall.
Reinstall strainer and vacuum ball float valve assembly
securely.
AS NEEDED
Lubricate pressure regulator O-ring (if equipped).
Access O-ring by unscrewing and removing pressure
regulator knob (Fig. 2H). Lubricate with a suitable O-ring
lubricant.
Lubricate the solution line quick-connect coupling
(Fig. 1D) with a small amount of rust-inhibiting oil such
as LPS-3 or WD-40.
07-02052E
All manuals and user guides at all-guides.com
6
To maintain appearance, wipe interior and exterior
surfaces with a damp cloth. For deep cleaning and a
lasting, protective shine, use an automotive vinyl
cleaner/protectant product.
MAINTENANCE (1200MS ONLY)
IMPORTANT! Pump crankcase oil must be changed
after an initial 50-hour break-in period. Thereafter, oil
must be changed every 3 months or at 500 hour
intervals thereafter. Replace only with General Pump Oil
according to the pump model numbers listed below. SAE
30W. Order part no. 13-030/24-00490.
To change the oil, see "Changing the 1200MS Pressure
Pump Oil" below.
FIG. 6: Recovery tank strainer
(pumpout models only)
Slide filter upward to remove. Rinse
filter clean with water and reinstall.