TYPICAL INSTALLATIONS
Housing mounted to
I-joists.
Housing mounted to joists.
Housing mounted anywhere
between trusses using
hanger bars.
PLAN THE INSTALLATION
1. Choose the
installation
location.
6-IN. ROUND
The location of
your humidity
sensing fan is
very important.
Use the follow-
ing guidelines
for best opera-
tion:
Housing mounted
anywhere between
I-joists using hanger bars.
Housing mounted
anywhere between
joists using hanger bars.
Housing mounted anywhere
between trusses using hanger
bars.
ROOF CAP
*
DUCT
*
6-IN. ROUND
Purchase
*
ELBOW
separately
• Locate unit above (GFCI protected circuit required) or
within 5 feet of shower head.
• Locate unit away from heating or cooling sources
which can affect humidity levels.
• Do not locate near window. Unit may respond to the
outdoor humidity level.
• Unit must be installed in ceiling to properly sense
moisture.
• Locate unit only on flat ceilings up to 12 feet high for
proper sensing.
• The fan will operate most efficiently when located
where the shortest possible duct run and minimum
number of elbows will be needed.
2. Plan the wiring.
• Plan to supply the unit with proper line voltage and
appropriate power cable. Power cable should be
routed to the switch box first and then to the unit
(See "CONNECT WIRING" on page 3).
• Do not operate this unit with a speed control.
Damage to the sensor unit will result.
• Light or night-light may be installed with a wall-
mounted motion control.
INSTALL HOUSING &
DUCT
1a. Mount
housing
to joist or
I-joist.
Use a pliers to
bend housing
TABS out
to 90
housing in
place so that
the housing
tabs contact
the bottom
of the joist.
The housing
*
mounts with
four (4) screws
or nails. Screw
or nail housing
to joist through
lowest holes in
each mounting
flange, then
through highest holes. NOTE: Mounting to I-JOIST
(shown) requires use of SPACERS (included)
between the highest hole of each mounting flange and
the I-joist.
WALL
*
CAP
MODEL QTX110SL
. Hold
0
(use for mounting to I-Joist)
OR
Page
TABS
SPACER
I-JOIST