Setting The Date And Time; Fault Management And Maintenance; Cleaning The Sensors And Transport Brush - Detectalia M8 Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

5.4. Setting the date and time

The third setting option in the setup is setting the time and the date. In the standard display, press the
"SET" button three times to open the menu point.
Press the "PRINT" button to toggle between Year (Y), Month (M), Day (D) and Time. You can adjust the
values by pressing the "+" and "-" keys.

6. Fault management and maintenance

The device is equipped with comprehensive fault management in order to inform you about problems in
the processing of money, but also to draw attention to the contamination of sensors. Please pay
particular attention to the following instructions for cleaning the machine in order to avoid errors caused
by contaminated sensors and to have an optimum result when counting coins.
Error code
ERR 1
ERR 2
ERR 3
ERR 4
ERR 5
ERR 6
ERR 7
ERR 8
ERR 9
CLOSE HOPPER

7. Cleaning the sensors and transport brush

Due to the coins and by the settling dust, deposits occur in front of the sensors of the machine and in the
transport area of the coins. These impurities can lead to problems during transport and to the sorting of
the coins.
Cause of error
Infrared error Sensor 1 (1 Cent)
Infrared error Sensor 2 (2 Cent)
Infrared error Sensor 3 (10 Cent)
Infrared error Sensor 4 (5 Cent)
Infrared error Sensor 5 (20 Cent)
Infrared error Sensor 6 (1.00 Euro)
Infrared error Sensor 7 (50 Cent)
Infrared error Sensor 8 (2.00 Euro)
Infrared error Hopper Sensor
After the machine has been opened, it has
been forgotten to push the safety-lock
slider back into the closed position.
Solution
Clean
the
corresponding
sensor, if the fault should not be
remedied, the corresponding IR
emitter must be replaced by the
service.
Place the Safety-Lock slider in the
closed position.