3. +/-: Short press to switch the +/- direction.
GB
4. In/mm: Short press to switch between mm and inch mode.
5. ZERO/ABS: Short press at any position for zero setting (relative measuring mode). "INC"
will be displayed on LCD. Press and hold for more than 3s to exit relative measuring
mode.
6. +/-: Short press to switch the +/- direction.
7. Preset mode:
7.1 Long Press "PRESET" key for 3 sec to the data setting mode. "P" twinkling on the
display.
7.2 Long Press "PRESET" key for 3 sec for cycle shift to the digit, short press to set value.
7.3 Long Press "PRESET" key for 3 sec after setting until "P" twinkling on the display.
Then short press "PRESET" key to save the preset value and exit setting mode.
8. Tolerance setting:
8.1 Long press "TOL" key for 3 sec to activate tolerance setting mode. "TOL" twinkles on
display.
8.2 Long press "TOL" key for 3 sec for cycle shift to the digit, short press to set value.
After setting value, long press "TOL" key until "TOL" twinkles. short press "TOL" key
to save the value. Upper and lower limit value can be set continuously.
8.3 After setting value, short press "TOL" key to save the value and into monitoring mode.
"TOL" will show on display.
8.4 "O" shows on display if value is within upper and lower value.
the upper limit.
BATTERY REPLACEMENT
Note: Remove battery if not use the caliper for long time.
4
Shows if exceeding the lower limit.
1
2
shows If exceeding