WARNINGS
• Please read the manual carefully before using the product and save it for futurereference.
• Place the appliance on a solid and stable table or surface being dry, ventilated and free from sunlight.
• When the appliance is being used, keep it out of reach of children to avoid any scalding accident.
• Please do not touch the vent hole in the top cover during use to avoid scalding.
• Do not put the main unit into any liquid during the cleaning process.
• Please disconnect the appliance from the power after each use.
• The appliance falls into Category I to be protected from electric shock, so it requires a two-conductor socket with reliable grounding, and a
leakage protector shall be connected for domestic power distribution.
• If the appliance malfunctions, disconnect it from the power. If the power cord is damaged, contact your after-sales service department or the
manufacturer to have it repaired by a quali ed service person.
• The user must strictly comply with the provisions about use and operation of this product.
I. PRODUCT COMPONENTS
1. Top cover handle; 2. Transparent top cover; 3. Nipple holder; 4. Disinfection holder; 5. Main unit; 6. Heating plate; 7. Switch knob;
Technical Speci cation: 220V~50HZ Disinfection: 500W Dry:130W

PRODUCT FEATURES

• This product is made of high-quality materials and carefully designed, featuring its beautiful appearance, compact structure, small size,
portability, being solid and practical, etc.
• It conforms to the food grade requirements with non-toxic plastics and does not contain bisphenol A t o secure its use by you and your baby.
• You can switch freely among the three modes: Sterilisation, Sterilisatio and semi-drying, Sterilisation and drying and also customize your
disinfection timeo to reduce waiting, thus being convenient and hygienic with a longer sterilized state.
• Its transparent window allows you to watch the disinfection process.
• Its large-capacity space can accommodate 6 di erent sizes milk bottles and other children dishware.
• With a intelligent program control switch, it can switch o and stop automatically at the end of each process.
II. OPERATING INSTRUCTION
1. Clean your milk bottle and other accessories before sterilization.
2. Pour about 100ML of pure water or distilled water into the sterilizer pan, do NOT exceed the maximum water level.
3. Put the disinfection holder into the main unit in the required direction, next place the bottle on the circular opening of the disinfection holder
(with the bottle mouth facing down), and the nipple and accessories on the upper nipple holder, and then put the transparent upper cover.
4. Power on and turn the switch to the position Sterilisation and drying" or "Sterilisation and semi-drying", and it can automatically dry after
sterilization. It can also be turned to the position "Sterilisation" for quick disinfection.
Quick semi-dry: it' s short and there may be steam droplets, but it does not a ect its use.
Disinfect for 10 minutes at most or automatically enter the drying function after water dries.
5. For sterilization of the bottle cap, it is recommended to disassemble and disintegrate it before sterilization.
If your baby's cutlery and utensils are sterilized in traditional ways of being bathed in hot water or boiled, there are some disadvantages:
1: The sterilization penetration of being bathed in hot water is not as good as that of high-temperature steam, and its sterilization e ect is not as
strong as that of steam sterilization;
2: If the boiling time is too long, those plastic appliances with low heat resistance are vulnerable to deformation;
3: Metal products, when heated in boiling water for a long time, are prone to being high-temperature, and may cause deformation or damage
to plastic products once contacting.
III. CLEANING AND MAINTENANCE
• Due to the di erent water quality in di erent areas, any scale found in the drying and sterilization device must be removed on a regular basis
to protect the health of your family and children. It is recommended to use pure water.
• Use citric acid: add an appropriate amount of water and then 10g citric acid, in which the transparent top cover needn't be added, switch on for
sterilization, and then wash with water for 5 to 6 times. Repeat the above steps when necessary.Use white vinegar: pour an appropriate amount
of white vinegar into the bottom sterilization plate of the main unit and let it stand for 1 hour without being heated. After discarding white
vinegar, wash with water for 5 to 6 times. Repeat the above steps when necessary.
• If the device is will not be used for long time, wipe and clean it and then put it into the packing box.
• Do not expose the appliance to the following substances or environments: (water, fog, steam, high temperature or sunlight).