Use
Attention: Always first connect the cleaning gun to the cooling hose, then to the water hose and
finally to the compressed air.
1. Drain the coolant into a suitable container. Observe disposal regulations.
2. Separate two radiator hoses from the cooling circuit.
3. Connect a hose with the proper size of the 5-stage nozzle and secure with a hose clamp (see
photo, item 1).
4. Direct the second hose as a drain into a suitable container. Observe disposal regulations.
5. Connect 1/2" coupling of the water hose to the cleaning gun (see photo, item 2).
6. Connect the cleaning gun to the compressed air system (see photo, item 3).
7. Press trigger of the cleaning gun (see photo, item 4). Because of the compressed air, which
increases the water pressure and thus the cleaning action, the cooling system is cleaned without
any solvents or aggressive chemicals.
8. After the cleaning procedure, the cleaning gun is separated first from the compressed air, then
from the water hose and finally from the radiator hose.