Stalgast 9715110 Manual De Instrucciones página 47

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 79
• for the 9kW burner, use of pots with diameters from 42 cm and higher is recommended
• for the 7kW burner, use of pots with diameters from 38 cm to 46 cm is recommended
• for the 5kW burner, using pots with diameters from 32 cm to 38 cm is recommended
• for 3.5kW burner, using pots with diameters from 28 cm to 32 cm is recommended
The bottom should be suita-
bly larger for this burner
• Do not use any dishes other than those intended for warming up. Use of inappropriate dishes (e.g. pla-
stic ones) may result in fire hazards.
• Make sure that all the knobs of the unused burners are in the „closed burner" position (Fig.6). pilot knobs
of stove burners are placed on the right side of the control panel (Fig.1, item 6).
Figure 6. Setting a knob in the position, in which the gas supply to the burner is completely cut off.
• Open the valve for LPG cylinders equipped with the LPG reductant (only for LPG-powered stoves).
• Press the control knob of the selected burner while holding the lit match or the lighting appliance (e.g.
electric lighter) in your hand.
• Turn the knob to the „pilot burner" position as shown in Fig. 7 (counterclockwise)
Figure 7. Setting the knob when only the pilot burner is gas-powered.
• gnite the gas via the „pilot burner" with the previously prepared match or lighting appliance, and press
and hold the knob for about 20 seconds (the time it takes for the protection to come into effect)
ATTENTION! When proceeding with ignition of the pilot burner, please remember that there is air in
the fitting, which must be displaced by the incoming gas from the supply system. When the gas has
filled the entire stove fitting, the unit actuates.
• Turn the knob (counterclockwise) to the full-flame position (Fig. 8) in order to light the main burner (lit
by the pilot burner). Then turn the knob further in the same direction to get an energy-saving flame
(Fig. 9). The main burner will not be actuated if the pilot burner does not light and heat the gas leak
detector. In the event of a temporary fadeaway of flame, the gas leak detector will cut off the gas supply
to the burner.
Concave bottom
- 47 -
Bottom too small for this
burner