Control Panel Indicators; Service Indicator; Pressure Control Knob Settings - Titan Impact 440 Instrucciones De Uso

Airless equipo de alta presión para pulverizar
Ocultar thumbs Ver también para Impact 440:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Impact 440
4.2

coNTrol pANel INDIcATorS

The following is a description of the control panel indicators.
Service
Indicator

ServIce INDIcATor

The Service indicator is on when the motor is commanded to
run. This indicator is used by service centers to troubleshoot
motor problems.
preSSure INDIcATor
The pressure indicator shows the current operating pressure of
the sprayer. It has three different indications: blinking yellow,
solid yellow, and solid green.
Blinking yellow
When the pressure indicator is blinking yellow, the sprayer is
operating between 0 and 1.4 MPa (14 bar). A blinking yellow
pressure indicator means:
The sprayer is plugged in and turned "ON"
The sprayer is at priming pressure (little or no pressure)
It is safe to move the relief valve between positions
It is safe to change or replace the spray tip
If the pressure indicator begins blinking yellow
i
when the pressure control knob is set at a higher
pressure and the relief valve is in the SPRAY
position, either the spray tip is worn or the
sprayer is in need of service/repair.
Solid yellow
When the pressure indicator is solid yellow, the sprayer is
operating between 1.4 MPa (14 bar) and 12 MPa (120 bar). A
solid yellow pressure indicator means:
The sprayer is at the proper pressure setting for spraying
stain, lacquer, varnish, and multi-colors
Solid green
When the pressure indicator is solid green, the sprayer is
operating between 12 MPa (120 bar) and 23 MPa (230 bar). A
solid green pressure indicator means:
The sprayer is at the proper pressure setting for spraying
oil-based and latex house paints
The sprayer is operating at peak performance at a high
pressure setting
If the pressure indicator goes to solid yellow when the
pressure is set so that it starts at solid green, it indicates
one of the following:
Pressure
Indicator
a. Tip Wear Indicator — when spraying with latex or at high
b. Tip Too large — when a tip that is too large for the sprayer
c. fluid Section Wear — if a solid yellow pressure indicator
4.3
1. Minimum pressure setting
2. Black zone – no pressure generation
3. Blue zone – pulsating pressure for cleaning
pressure the solid yellow appears. This means the tip is
worn and needs to be replaced.
is put in the gun, the pressure indicator will turn from solid
green to solid yellow.
appears when using a new tip and the pressure is set at
maximum, service may be required (worn packings, worn
piston, stuck valve, etc...).

preSSure coNTrol kNoB SeTTINgS

1
2
3
starting operation
13
Tabla de contenido
loading

Tabla de contenido