Safe Installation; Power; M3 Motor + Power Supply 24 Vac; Input And Output Connections And Functions - O&O LOG-BC Manual De Instalación

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

In order to reach the level of safety required by current standards, read the following prescriptions carefully.
Do all the connections on the terminal block, reading the instructions given in this manual carefully and observing the general code of
1)
practice regulating the execution of electrical installations.
Install a four-pole circuit breaker upstream from the installation with a minimum contact opening distance of 3 mm.
2)
3)
Install, wherever it is not foreseen, a differential switch with a 30 mA threshold.
Check effectiveness of the earthing system and connect to it all parts of the automation that have a terminal or earth wire.
4)
There must be at least one signalling device outside, either a traffic light type or a flashing light, together with either a danger or
5)
warning sign.
Apply all the safety devices required by the type of installation, considering the risks it can cause.
6)
7)
Separate the power lines (min. 1,5 mm
Jumper the unused NC inputs.
8)
9)
Arrange in series any contacts to be connected to the same NC input.
10)
Arrange in parallel the inputs connected to the same NO input.
Keep radio control or other control devices out of children's reach, in order to avoid any unintentional automation activation.
11)
230V LINE
F
- Transformer input at 230V 50/60Hz
230 V ~
- Connect the earthing pole in the relevant terminal.
N
- Power the gear motor via the 3-way terminal
protected by 1A fuse (5x20).
- Utilise an H07RN-F 2x1.5+T min type cable
MOT1 - MOT2
Motor output 24Vdc. After a power failure, the first action performed is an opening cycle.
If it fails, stop the automation, take the motor connector out and put it back in the other way around.
+ACC
TRAS 2
TRAS1 - TRAS2
TRAS 1
24 Vac input for transformer. Connection to the control unit
MOT2
is shown in the figure here
MOT1
+ACC
Do not use

6. INPUT AND OUTPUT CONNECTIONS AND FUNCTIONS

OUT 24V
-
+
Accessories power supply (max 12 W):
24 Vac operations with mains power on.
OUT 24V
24 Vdc (out+, 24V-) operation with no main power and optional buffer battery kit. KIT-BATT-SC
SCA 24Vac 3W max
Carriageway open LED that flashes slowly during opening, rapidly during closing, remains lit steady during the stop and
pause phase and switches off when the barrier is closed.
N.B.: The indicator lamp flashes twice to indicate that the automation system has detected an obstacle three consecutive
OUT 1
times while closing. Automatic closing is temporarily disabled and is enabled again only after a subsequent successful
closing cycle.
YELLOW FLASHING LAMP (SL-R-24V-AI) 24Vac 25W max.
Flashing output for self-flashing blinker
OUT 2
NOT USED
OUT 3
All manuals and user guides at all-guides.com

4. SAFE INSTALLATION

cross section) from the low voltage signal lines (min. 0,5 mm
2

5. POWER

5.1
MOTOR + POWER SUPPLY 24 Vac
M3
6.1
POWER TERMINAL BLOCK
M1
1A
- 12 -
cross section) in the ducts.
2
F N
(230V)
TRANSFORMER
Tabla de contenido
loading

Tabla de contenido