Wired Controller CDV 57
P43
Set priority operation
If warmth-preservation
function
P46
when the water tank is
in standby status
The temperature sett-
ing value of warmth-
P47
preservation function
when the water tank is
in standby status
Set the sunflower heat
P50
preservation water te-
mperature
Automatically set mo-
P53
dification value of hot
water temperature
Days for circulation of
P54
high temperature ste-
rilization
Time for starting high
P55
temperature steriliza-
tion in advance
00: normal operation
01: priority operation
00:allow
is
allowed
01:Not allow
35~46℃
35~50℃
-2~8℃
0~60day
0-3h
00
00
42℃
40℃
0℃
0
1
20
When power supply is
insufficient, the water tanks or
hot water generators, which
are set to priority operation,
can operate, while other water
tanks or hot water generators
are forced to be turned off.
--
--
When the setting is 0, the
function of high temperature
sterilization is valid for once
and will not be memorized.
--