SPECIFICATIONS
Type
Dynamic (moving coil)
Frequency Response
80 to 15,000 Hz
Polar Pattern
Cardioid
Output Impedance
EIA rated at 150Ω (270Ω actual)
Sensitivity
H: −37 dBV/Pa (14.1 mV)
(at 1 kHz, open circuit
L: −55.5 dBV/Pa (1.7 mV)
voltage)
1 Pascal=94 dB SPL
Polarity
Positive pressure on diaphragm produces positive voltage
on pin 2 with respect to pin 3
Weight
Net: 0.315 kg (0.69 lbs)
Connector
Three-pin professional audio (XLR), male
Case
Platinum beige enamel die casting with platinum beige
steel grille
IMPEDANCE SELECTION
The microphone is shipped connected for low impedance operation. To change to high
impedance proceed as follows:
1.
Loosen plug element by turning slotted setscrew counterclockwise (turn counterclock-
wise to lower screw into plug element). Pull plug element from case. Be careful not to
stretch or break wires.
2.
The low impedance socket of the impedance selection connector is connected to Pin
3 of the plug element. Move the connector to the high-impedance socket (see wiring
diagram).
3.
Reinsert plug element and tighten setscrew (turn clockwise to raise screw).
SET SCREW
IMPEDANCE SELECTION CONNECTOR
4
4
All manuals and user guides at all-guides.com
ACCESSORIES AND PARTS
Furnished Accessories
Swivel Stand Adapter
Optional Accessories
Desk Stand
Isolation Mount
Windscreen (6 colors available)
4.6 m (15 ft.) 1-conductor with phone plug (High Impedance)
6.1 m (20 ft.) Cab; (XLR-1/4 in.)
Replacement Parts
Cartridge
Screen and Grille Assembly
CERTIFICATION
Eligible to bear CE Marking. Conforms to European EMC Directive 2004/108/EC. Meets
Harmonized Standards EN55103-1:1996 and EN55103-2:1996, for residential (E1) and light
industrial (E2) environments.
The Declaration of Conformity can be obtained from:
Authorized European representative:
Shure Europe GmbH
Headquarters Europe, Middle East & Africa
Department EMEA Approval
PLUG ELEMENT
Phone: +49 7
Fax: +49 7
E-Mail:
, Germany
@shure.de
A25D
S37A
A53M
A58WS
C15AHZ
C20AHZ
R180
RK332G