Indication light
Check if the freezer is connected to a power
does not light up
source;
Check if the light is damaged.
The freezer's
Check if the freezer's door is stuck by food
door cannot be
packages;
properly closed
Check if there is too much food;
Check if the freezer is unbalanced.
Loud noises
Check if the floor is flat and if the surface
where the freezer is placed is stable;
Check if the freezer's accessories are properly
placed.
Transient
After refrigeration, there will be a pressure
difficulty while
difference between the freezer's inside and
opening the
outside that will result in a transient difficulty
door
while opening the door.
This is a normal physical phenomenon.
Heat and
The freezer's enclosure may emit heat during
condensation
operation, especially in summer; this is caused
building up
by the condenser's radiation, and it is a normal
inside the
phenomenon.
freezer's
Condensation: a condensation phenomenon
enclosure
will be detected on the freezer's exterior surface
and door seals when the ambient humidity
is high; this is a normal phenomenon,
and the condensation can be wiped away
with a dry towel.
Airflow sound
Refrigerants circulating in the refrigerant lines
will produce sounds and grunts, which is normal
Buzz
and does not affect the cooling effect.
Clatter
Buzz will be generated by the running
compressor, especially when starting
up or shutting down.
3. TECHNICAL SPECIFICATIONS
Table 1 - Climate classes
Class
Symbol
Extended temperate
SN
Temperate
Subtropical
ST
Tropical
Ambient temperature
range °C
+ 10 to + 32
N
+ 16 to + 32
+ 16 to + 38
T
+ 16 to + 43
22
chest freezer
Extended temperate: this refrigerating appliance is intended to be
used at ambient temperatures ranging from 10° C to 32° C.
Temperate: this refrigerating appliance is intended to be used at
ambient temperatures ranging from 16° C to 32° C.
Subtropical: this refrigerating appliance is intended to be used at
ambient temperatures ranging from 16° C to 38° C.
Tropical: this refrigerating appliance is intended to be used at
ambient temperatures ranging from 16° C to 43° C.
Special for new European standard
The ordered parts in the following table can be acquired from several
channels.
Ordered Part
Provided by
Thermostats
Professional
maintenance
personnel
Temperature
Professional
sensors
maintenance
personnel
Printed circuit
Professional
boards
maintenance
personnel
Light sources
Professional
maintenance
personnel
Door handles
Professional
repairers and
final users
Door hinges
Professional
repairers and
final users
Trays
Professional
repairers and
final users
Baskets
Professional
repairers and
final users
Door gaskets
Professional
repairers and
final users
23
EN
KCF5215
KCF5216
Minimum Time Required
for Provision
At least 10 years after the last
model is launched on the market
At least 10 years after the last
model is launched on the market
At least 10 years after the last
model is launched on the market
At least 10 years after the last
model is launched on the market
At least 10 years after the last
model is launched on the market
At least 10 years after the last
model is launched on the market
At least 10 years after the last
model is launched on the market
At least 10 years after the last
model is launched on the market
At least 10 years after the last
model is launched on the market