Astralpool KEOPS Manual De Instrucciones Y Mantenimiento página 10

Casetas de filtración compactas
Ocultar thumbs Ver también para KEOPS:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
11. Turn the pump on.
12. Put the housing cover(s) back on by screwing the screws back in at the rear of the cover(s).
Turn the pump off whenever the selector valve is being handled. Otherwise the filter and the whole
installation could be damaged.
It is recommended that a lock or padlock be fitted to prevent children or unauthorized persons from
getting into the housing.
Before switching the unit on, check the calibration of the motor protection circuit breakers, and that
protection devices against electric shocks and mechanical failures are properly positioned and fitted.
Do not start the pump up if there is no water in the pool.
Do not run the filtration unit if the water level does not cover the skimmer's flap.
3.1. PUMP
Before starting the pump up, perform the following operations:
Take the prefilter cover off.
Prefilter cover
Seating joint to be cleaned
Fill the pump with water through the prefilter until it flows out of the suction conduit.
Put the basket back inside the prefilter, if it had to be removed to perform the previous operations, so that large
particles are unable to get inside the pump that could block it.
Check that the mains voltage and frequency correspond to the figures displayed on the pump's rating plate.
Put the prefilter cover in place and close it, without forgetting to place the seal in its housing.
10
COMPACT FILTRATION HOUSING -
INSTRUCTION AND MAINTENANCE MANUAL
Tower joint
Prefilter
Basket
Tabla de contenido