Assembly
1. Flush through the supply pipes.
2. Mount the ball S - unions.
Hot water connection left hand, cold water
connection on the right hand side.
3. Fasten the mixer using ball union nuts, align and
tighten it. The ball S - unions enable inaccuracies
in the wall installation to be compensated for,
whether in the horizontal direction, in the vertical
direction or in the parallel orientation.
4. Screw the escutcheons down the wall.
Large differences in pressure between the hot and
cold water supply should be balanced.
Adjustment
Correction is necessary if the temperature measured
at the take off point differs from the temperature set
on the scale. To adjust please see page 13.
Operation
The mixer is operated by turning the handle on the
left hand side. The green knob limits the rate of flow
to approx. 10 l/min. If a higher water consumtion
is required press the ECOSTOP button and turn
handle further.
The temperature is selected by turning the graduated
handle on the right side. The flow of the bath mixer
can be changed from tub to shower function by
simply pulling the diverter knob located at the top
of the outlet.
When the water is shut off the flow returns
automatically to the bath function.

Temperature limitation

The temperature is limited by the safety check to 38° C
(100° F). If a higher temperature is required, it is possible to
override the safety stop by depressing the safety button.
To garantee a smooth running of the thermoelent, it
is necessary from time to time to turn the thermostat
from total hot to total cold.
The mixer is equipped with non return valves and
filters. If the water flow drops the non return valves
need to be cleaned. For that purpous the mixer has to
be removed from the wall. The filters are located in the
connection pieces underneath the connecting nuts.
6
English
Attention!
The non return valves must be checked regularly
according to DIN EN 1717 in accordance with national
or regional regulations (at least once a year)
Using the Ecostat in conjunction with
combination boilers.
When using the Ecostat with combination boilers,
the Ecostop ring "A" has to be removed.
If fitting a hand shower remove the water limiter
from the shower. (Please see page 14)
Technical Data
Operating pressure:
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 0,3 MPa:
Test certificates:
Anti-pollution-function
Spare parts (see page 3)
1
thermoelement
2
shut off unit
3
knob for thermoelement
4
knob for shut off unit
5
aerator cpl.
aerator gold plated
6
spout cpl.
7
diverter knob
8
selector cpl.
9
non return valve DW 16
10 filter
11 ball s-unions
12 safety set for temperature control 95041000
13 safety set for flow control
XXX = Colours
000 chrome
090 chrome/gold
450 white
810 satinox
max. 1 MPa
1,6 MPa
max. 80° C
65° C
20 l/min
WRAS
MSA
94282000
94149000
96217XXX
96218XXX
13485000
94981990
92460XXX
94102XXX
94103000
95033000
95039000
13989000
95042000
Tabla de contenido