EMERGENCIES: If a gas leak cannot be stopped, or a fire occurs due to gas leakage, call the fire department.
Gas leaking from
• Damaged hose.
cracked/cut/burned hose.
Gas leaking from LP
• Mechanical failure due to rusting or
cylinder.
mishandling.
Gas leaking from LP
• Failure of cylinder valve from mishandling
cylinder valve.
or mechanical failure.
Gas leaking between LP
• Improper installation, connection not
cylinder and regulator
tight, failure of rubber seal.
connection.
Fire coming through
• Fire in burner tube section of burner due
control panel.
to blockage.
Grease fire or continuous
• Too much grease buildup in burner area.
excessive flames above
cooking surface.

Troubleshooting

Problem
Possible Cause
GAS ISSUES:
Burner(s) will not light
• Trying to light wrong burner.
using ignitor.
(See Electronic Ignition
• Burner not engaged with control valve.
Troubleshooting also)
• Obstruction in burner.
Continued on next
page.
• No gas flow.
• Vapor lock at coupling nut to LP cylinder.
• Coupling nut and LP cylinder valve not
fully connected.
ELECTRICAL ISSUES:
• Electrode cracked or broken; "sparks at
crack.
• Electrode tip not in proper position.
• Wire and/or electrode covered with
cooking residue.
• Wires are loose or disconnected.
• Wires are shorting (sparking) between
ignitor and electrode.
• Dead battery.
All manuals and user guides at all-guides.com
•Turn off gas at LP cylinder or at source on natural gas systems. If the
hose is cracked or cut but not burned, simply replace valve / hose /
regulator. If the hose is burned, the cause could be other than a
faulty valve/hose/regulator. Discontinue use of grill until a plumber or
gas technician has investigated and corrected the problem.
• Replace LP cylinder.
• Turn off LP cylinder valve. Return LP cylinder to gas supplier.
•Turn off LP cylinder valve. Remove regulator from cylinder and
visually inspect rubber seal for damage. See LP Cylinder Leak Test
and Connecting Regulator to the LP Cylinder.
•Turn off control knobs and LP cylinder valve. Leave lid open to allow
flames to die down. After fire is out and grill is cold, remove burner
and inspect for spider nests or rust. See Spider Alert and Cleaning
the Burner Assembly sections of this Use & Care Guide.
• Turn off control knobs and LP cylinder valve. Leave lid open to allow
flames to die down. After cooling, clean food particles and excess
grease from inside firebox area, grease tray, and other surfaces.
Prevention/Solution
• See instructions on control panel and in Use and Care section.
• Make sure valves are positioned inside of burner tubes.
• Ensure burner tubes are not obstructed with spider webs or other
matter. See cleaning section of Use and Care.
• Make sure LP cylinder is not empty. If LP cylinder is not empty,
refer to "Sudden drop in gas flow."
• Turn off knobs and disconnect coupling nut from LP cylinder.
Reconnect and retry.
• Turn the coupling nut approximately one-half to three-quarters
additional turn until solid stop. Tighten by hand only - do not use
tools.
• Replace electrode(s).
Main Burners:
• Tip of electrode should be pointing toward gas port opening on
burner. The distance should be 1/8" to 1/4". Adjust if necessary.
• Clean wire and/or electrode with rubbing alcohol and clean swab.
• Reconnect wires or replace electrode/wire assembly.
• Replace ignitor wire/electrode assembly.
• Replace with a new AAA-size alkaline battery.