4 • fEaTuRES
green LED (fig. 1a)
lights up
continuously
flashes (over approx.
10 min. period)
GB
lights up
continuously
lights up
continuously
lights up
continuously
lights up
continuously
5 • TESTINg / MaINTENaNCE
The detector can be fully tested using the test button (fig. 1d). Perform a test at least once
a month. Press the test button (for up to 5 seconds) until a loud, pulsating alarm signal
(approx. 85 dB) can be heard. When necessary (usually about twice a year), wipe the
device with a clean, dry cloth and clean the outside with a vacuum cleaner. The device
automatically performs a test. If there is a fault, the orange LED (fig. 1b) will light up
continuously. This indicates that the detector needs to be replaced.
NOTE: To ensure your safety, the PROTECTOR GD 230 V ∼ is designed to be highly sensitive.
For this reason, the sensor may also react to other gases (e.g. propellants in aerosol spray cans
and disinfectant sprays).
6 • aCCESSoRIES
ESYLUX PROTECTOR switching relay
7 • aCTIoN IN THE EVENT of aN alaRM
• Do not smoke. Do not light a flame.
• Do not unplug the PROTECTOR GD 230 V ∼ or any other device from the mains.
• Press the test button (fig. 1d) to silence the PROTECTOR GD 230 V ∼ for approx.
10 minutes.
• Open doors and windows fully. When ventilating the building, please note the
properties of the particular gas:
- Natural gas (CNG, methane) is lighter than air and collects beneath the ceiling.
- Liquefied/bottled gas (LPG, propane/butane) is heavier than air and collects at floor level.
• Disconnect the gas supply at the main cock/bottle valve.
• Arrange for an engineer to check your gas appliance.
8
orange LED (fig. 1b)
red LED (fig. 1c)
off
off
off
off
off
flashes
leuchtet
off
permanent
flashes
flashes
off
flashes
Alarm signal/Piezo
Description
device is
off
operational
off
warm-up phase
alarm, see
intermittent alarm
Section 7 for
signal
action to take
fault,
off
change device
intermittent alarm
Testalarm
signal
short beep every
alarm has been
45 sec.
silenced