Korenix JetNet 5728G Serie Guía De Instalación Rápida página 7

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

JetNet 5720G-8P
Power Supply
Input Range
Type
Mix
48VDC
46 VDC
(IEEE802.3af)
53 VDC
52 VDC
(IEEE802.3at)
Note 1: (F) Denotes fast-acting fuse, (T) denotes time-delay fuse
Note 2: Power consumption varies based on configuration. 10/100Tx ports consume
rating of fuse.
4.3 Wiring Digital Output
JetNet 5728G/5720G provides 1 digital output, also known as Relay Output. The relay
contacts are energized (open) for normal operation and will close for fault conditions. The
Wiring digital output is exactly the same as wiring power input introduced in chapter 2.2.
4.4 Wiring Earth Ground
To ensure the system will not be damaged by noise or any electrical shock, we suggest
you to make exact connection with JetNet 5728G/5720G with Earth Ground.
On the back panel of JetNet 5728G/5720G, there is one earth ground screw. Loosen
the earth ground screw by screw drive; then tighten the screw after earth ground wire is
connected.
Fuse
Rating
Max
Worst Case
57 VDC
1.5 A (F)
123.2W
57 VDC
1.5 A (F)
182W
Power Consumption
Max
123.2W
240W
Tabla de contenido
loading

Este manual también es adecuado para:

Jetnet 5728g-24pJetnet 5728g-16pJetnet 5720g-8p

Tabla de contenido