Technical Data

Tool Data
Free speed (rpm)
Max. torque (reverse)
(ft.lb)
Max. torque (reverse) (Nm)
Min. working torque for-
ward
(ft.lb)
Max. working torque for-
ward (ft.lb)
Min. working torque (Nm)
Max. working torque (Nm)
Weight (kg)
Weight (lb)
Maximum working pressure
6.3 bar / 90 psig
Declarations
EU DECLARATION OF CONFORMITY
We, Fuji Industrial Technique Co., Ltd., 2-1-14, Kamiji,
Higashinari Ku, Osaka, Japan, 537-0003 , declare under our sole
responsibility
that the product (with name, type and serial
number, see front page) is in conformity with the following
Directive(s):
2006/42/EC (17/05/2006)
Harmonized standards applied:
EN ISO 11148-6:2013
Authorities can request relevant technical information from:
Pascal Roussy, R&D Manager, Ets Georges Renault, 38 rue
Bobby Sands, BP10273 44818 Saint Herblain, France
Saint-Herblain,
Pascal ROUSSY
Signature of issuer
FW-330-1C
FW-330-1CL
N EC
N EC
5000
5000
1917
1917
2600
2600
369
369
1549
1549
500
500
2100
2100
10.7
12.2
23.6
26.9
© Fuji- 9502001210
Noise and vibration
Sound pressure level
(dB(A))
Vibration uncertainty
Vibration (m/s²)
Uncertainty 3 dB(A), in accordance with EN ISO 15744. For
Sound power level, add 11 dB(A)
Vibration standard : ISO-28927-2
These declared values were obtained by laboratory type testing
in accordance with the stated standards and are suitable for com-
parison with the declared values of other tools tested in accor-
dance with the same standards. These declared values
are not adequate for use in risk assessments and values
measured in individual work places may be higher. The actual
exposure values and risk of harm experienced by an individual
user are unique and depend upon the way the user
works, the workpiece and the workstation design, as well
upon the exposure time and the physical condition of the
user.
We, Fuji Industrial Technique Co., Ltd., cannot be held liable
for the consequences of using the declared values, instead of val-
ues reflecting the actual exposure, in an individual risk assess-
ment in a work place situation over which we have no control.
This tool may cause hand-arm vibration syndrome if its use
is not adequately managed. An EU guide to managing handarm
vibration can be found by accessing
index.php
and selecting 'Tools' then 'Legislation'.
We recommend a programme of health surveillance to detect
early symptoms which may relate to noise or vibration exposure,
so that management procedures can be modified to help
prevent future impairment.
If this equipment is intended for fixtured applications:
The noise emission is given as a guide to the mchine-
builder.
Noise and vibration emission data for the complete
machine should be given in the instruction manual
for the machine.
Impact Wrench
FW-330-1C N
FW-330-1CL
EC
N EC
103.6
103.6
3.51
2.85
10.76
9.16
http://www.pneurop.eu/
5