Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

DC Alarm Kit
K74-18655 for SW420, SW470, and SW490 Operators
REMOVE THE EXISTING DC ALARM
1. Disconnect power from the operator.
2. Disconnect the wire harness from the main board connections
J1-16 and J1-12 (Figure 1).
NOTE: The J1 terminal block can be removed from the main
board to aid in wiring. If you remove the terminal block, make
sure to replace it securely on the main board.
3. Remove the existing alarm and wire harness (Figure 2).
FIGURE 1
J1 TERMINAL BLOCK
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Black wire (-) from alarm
Main board
Alarm
AC ALARM
DC ALARM
Removable
connector
Components covered
with heat shrink
Red wire (+) from alarm
LAYOUT FOR SW470 SHOWN
Flange
To reduce the risk of INJURY or DEATH:
• Disconnect all power BEFORE installing or servicing operator.
• See manual prior to servicing regarding maintenance and
required safety testing.
WARNING: This product can expose you to chemicals
including lead, which are known to the State of
California to cause cancer or birth defects or other
reproductive harm. For more information go to
www.P65Warnings.ca.gov.
CARTON INVENTORY
Alarm with wire harness (1)
Extra blue wire stripped on both sides (connects J1-3 to
J1-15) (1)
Wire ties (4)
Flange (41-G0538) (1)
TOOLS NEEDED
Pliers
#2 Phillips Head screwdriver
1/8" flat Phillips Head screwdriver
Old alarm
Diagonal wire cutters
Wire strippers
FIGURE 2
For reference only. Your equipment may look different.
Existing alarm
Operator chassis
Operator chassis
Plastic nut
Regulator
J1 TERMINAL BLOCK
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Black wire (-) from alarm
Red wire (+) from alarm
Flange
Plastic nut
Flange
Plastic nut
Tabla de contenido
loading

Resumen de contenidos para LiftMaster K74-18655

  • Página 1 DC Alarm Kit K74-18655 for SW420, SW470, and SW490 Operators AC ALARM To reduce the risk of INJURY or DEATH: • Disconnect all power BEFORE installing or servicing operator. • See manual prior to servicing regarding maintenance and required safety testing.
  • Página 2 INSTALL THE NEW DC ALARM 1. Insert the provided alarm flange onto the FIGURE 3 TERMINAL BLOCK LOCATED ON THE CHASSIS chassis using the mounting holes that held P1 P2 P3 P4 R1 R2 R3 R4 B the old alarm. 2.
  • Página 5: Kit De Alarma De Cc

    Kit de alarma de CC K74-18655 para operadores SW420, SW470, y SW490 AC ALARM Para reducir el riesgo de LESIONES GRAVES o la MUERTE: • Desconecte toda la alimentación ANTES de instalar o realizar el mantenimiento del operador. • Consulte el manual antes de realizar el mantenimiento y las pruebas de seguridad necesarias.
  • Página 6: Instalar La Nueva Alarma De Cc

    INSTALAR LA NUEVA ALARMA DE CC 1. Inserte la brida de la alarma suministrada en FIGURA 3 BORNERA UBICADA EN EL CHASIS el chasis utilizando los orificios de montaje P1 P2 P3 P4 R1 R2 R3 R4 B que sujetaban la alarma antigua. 2.
  • Página 9: Contenu De La Boîte

    Trousse d’alarme c. c. K74-18655 pour actionneurs SW420, SW470, et SW490 AC ALARM Pour réduire le risque de BLESSURES GRAVES, voire MORTELLES : • Déconnecter l’alimentation AVANT de procéder à l’installation de l’actionneur ou à une intervention d’entretien sur celui-ci.
  • Página 10 INSTALLER L’ALARME C. C. NEUVE 1. Insérer la bride d’alarme fournie dans les FIGURE 3 BORNIER SITUÉ SUR LE CHÂSSIS orifices de montage du châssis qui retenaient P1 P2 P3 P4 R1 R2 R3 R4 B l’ancienne alarme. 2. Monter l’alarme dans la bride (Figure 3). Écrou en plastique Bride Déposer l’écrou de plastique de l’alarme.
  • Página 12 © 2016, LiftMaster All Rights Reserved Todos los derechos reservados 01-18651C Tous droits réservés...

Tabla de contenido