16
1 Bit
17
1 Bit
18
1 Bit
19
1 Bit
20
1 Bit
21
1 Bit
22
1 Byte
23
1 Bit
24
1 Bit
25
1 Bit
26
1 Byte
27
1 Bit
28
1 Byte
29
1 Bit
30
1 Bit
31
1 Byte
32
1 Bit
33
1 Bit
34
1 Bit
35
2 Bytes
36
2 Bytes
37
1 Bit
38
1 Bit
39
1 Bit
40
1 Bit
41
1 Bit
42
1 Bit
43
1 Bit
44
1 Bit
45
1 Bit
46
1 Bit
47
1 Bit
48
1 Bit
49
1 Bit
50
1 Bit
51
1 Bit
52
1 Bit
53
1 Byte
54
1 Byte
http://www.zennio.com
O
C T R - -
DPT_Switch
O
C T R - -
DPT_Switch
O
C T R - -
DPT_Switch
O
C T R - -
DPT_Switch
O
C T R - -
DPT_Switch
I
C - - W U
DPT_Step
I
C - - W U
DPT_SceneControl
I/O
C T R W U
DPT_Switch
I
C - - W U
DPT_Switch
O
C T R - -
DPT_Switch
O
C T R - -
-
O
C T R - -
DPT_Switch
O
C T R - -
-
I
C - - W U
DPT_Switch
O
C T R - -
DPT_Bool
O
C T R - -
DPT_Scaling
I
C - - W U
DPT_Switch
I
C - - W U
DPT_Switch
O
C T R - -
DPT_Switch
I
C - - W U
DPT_Value_Temp
O
C T R - -
DPT_Value_Temp
I
C - - W -
DPT_Bool
I
C - - W -
DPT_Bool
I
C - - W -
DPT_Bool
I
C - - W -
DPT_Bool
I
C - - W -
DPT_Bool
I
C - - W -
DPT_Bool
I
C - - W -
DPT_Bool
I
C - - W -
DPT_Bool
I
C - - W -
DPT_Bool
I
C - - W -
DPT_Bool
I
C - - W -
DPT_Bool
I
C - - W -
DPT_Bool
I
C - - W -
DPT_Bool
I
C - - W -
DPT_Bool
I
C - - W -
DPT_Bool
I
C - - W -
DPT_Bool
I
C - - W -
DPT_Value_1_Ucount
I
C - - W -
DPT_Value_1_Ucount
0/1
Recepción Modo Auto
0/1
Recepción Modo Frío
0/1
Recepción Modo Calor
0/1
Recepción Modo Ventilación
0/1
Recepción Modo Seco
0/1
Envío Viento [1 bit]
0-63; 128-191
Escenas
0/1
Limitación de Temperatura
0/1
Apagado Automático
0/1
Error Interno
1-4
Tipo de Error Interno
0/1
Error Externo
0-255
Tipo de Error Externo
0/1
Envío Modo Humectación
0/1
Recepción Modo Humectación
0% - 100%
Recepción Nivel Humectación
0/1
Envío Nivel Humectación Pasos
0/1
Envío Lamas Extra
0/1
Recepción Lamas Extra
16ºC – 32ºC
Temperatura Ambiente
16ºC – 32ºC
Temperatura Modificada
0/1
[FL] Dato (1bit) 1
0/1
[FL] Dato (1bit) 2
0/1
[FL] Dato (1bit) 3
0/1
[FL] Dato (1bit) 4
0/1
[FL] Dato (1bit) 5
0/1
[FL] Dato (1bit) 6
0/1
[FL] Dato (1bit) 7
0/1
[FL] Dato (1bit) 8
0/1
[FL] Dato (1bit) 9
0/1
[FL] Dato (1bit) 10
0/1
[FL] Dato (1bit) 11
0/1
[FL] Dato (1bit) 12
0/1
[FL] Dato (1bit) 13
0/1
[FL] Dato (1bit) 14
0/1
[FL] Dato (1bit) 15
0/1
[FL] Dato (1bit) 16
0 - 255
[FL] Dato (1byte) 1
0 - 255
[FL] Dato (1byte) 2
KLIC-DD
1=Modo Auto Activado;0=Desacti
1=Modo Frío Activado;0=Desacti
1=Modo Calor Activado;0=Desact
1=Modo Ventilacion Activ;0=Des
1=Modo Seco Activado;0=Desact
0=Disminuir;1=Aumentar
Valor=Escena elegida
0=Deshabilitar;1=Habilitar
0=Deshabilitar;1=Habilitar
0=No hay Error; 1=Sí hay Error
1=Rec.Errónea,2=Tiempo Ag...
0=No hay Error; 1=Sí hay Error
Ver Tabla de Errores
1=Habilitar modo,0=Ignorar
0=Desactivado,1=Activado
0=Off,25=Baj,50=Med,75=Alto...
0=Disminuir,1=Incrementar
0=Parar,1=Mover
0=Paradas,1=Movimiento
Temperatura desde KNX
Temp.Real Enviada a la Máquina
Dato de entrada binario (0/1)
Dato de entrada binario (0/1)
Dato de entrada binario (0/1)
Dato de entrada binario (0/1)
Dato de entrada binario (0/1)
Dato de entrada binario (0/1)
Dato de entrada binario (0/1)
Dato de entrada binario (0/1)
Dato de entrada binario (0/1)
Dato de entrada binario (0/1)
Dato de entrada binario (0/1)
Dato de entrada binario (0/1)
Dato de entrada binario (0/1)
Dato de entrada binario (0/1)
Dato de entrada binario (0/1)
Dato de entrada binario (0/1)
Dato de entr. de 1byte (0-255)
Dato de entr. de 1byte (0-255)
Soporte técnico:
http://support.zennio.com
26