10. Charger indicator

Indicator status
Red LED
Green LED
Off
Flashing
On
Off
Off
On
Flashing
Off
Flashing
Flashing
On
On
Anl_TE_MG_12_1_Li_SPK9.indb 21
Anl_TE_MG_12_1_Li_SPK9.indb 21
GB
Explanations and actions
Ready for use
The charger is connected to the mains and is ready for use; there is no
battery pack in the charger
Charging
The charger is charging the battery pack in quick charge mode.
The battery pack is fully charged (charging completed)
Action:
Take the battery pack out of the charger. Disconnect the charger from
the mains supply.
Adapted charging
The charger is in gentle charging mode. For safety reasons the char-
ging is performed less quickly and takes more than 1,5 hour. The rea-
sons can be:
- The battery pack has not been used for a very long time or an alrea-
dy flat battery was further discharged (exhaustive discharge)
- The battery pack temperature is outside the ideal range (between
10° C and 45° C).
Action:
Wait for the charging to be completed; you can still continue to charge
the battery pack.
Fault
Charging is no longer possible. The battery pack is defective.
Action:
Never charge a defective battery pack. Take the battery pack out of the
charger.
Temperature fault
The battery pack is too hot (e.g. due to direct sunshine) or too cold
(below 0° C).
Action:
Remove the battery pack and keep it at room temperature
(approx. 20° C) for one day.