Motion SenSor inStruction Manual
Congratulations on selecting your new Landscape
Lighting Motion Sensor. The HRL-100-MS (part number:
06730) connects directly into the Hydro-Rain
®
3-Station LED
Landscape Light Controller/Transformer to provide additional
security, comfort, and beauty to your home and yard.
Motion SenSor FeatureS:
• Passive Infrared Motion Sensor
• 120° motion detection
• Up to 40 ft. range
• Wall or yard mounting (stake included)
inStallation:
tools required:
• Wire Cutters/Strippers
• Phillips Screwdriver
• Two screws (if wall mount is desired)
• Drill Bit (if wall mount is desired)
• Power Drill (if wall mount is desired)
Yard installation:
1. Select a location in your yard, such as a flowerbed
or garden, near an area you want motion to be
detected
2. Insert stake until platform is flush and level with
the ground
3. Adjust the sensor head to optimize motion
detection, pointing it towards the area most likely
to receive motion
note: The Motion Sensor should not be placed in
a location that is beyond the length of its chord
(approximately 8 ft.).
All manuals and user guides at all-guides.com
Wall installation:
1. Select a location on a wall near an area you want
motion to be detected
s
n
o
s i
n
e
m
2. Remove sensor head from plastic stake by sliding
the head up
0 "
7
2 .
3. Install a screw into the lower pre-formed hole
before doing the same with the upper pre-formed
hole
4. Adjust the sensor head to further optimize motion
detection
note: The Motion Sensor should not be placed in
a location that is beyond the length of its chord
(approximately 8 ft.).
connecting your Motion Sensor to terminal:
1. Separate the three wires, only enough for
installation, connected to your motion sensor
2. Strip ½ inch (12 mm) of the plastic insulation
off the end of each wire
t
n
u
o
M
e
k
a
t
S
t
n
u
o
M
l
a l
W
3. Loosen the necessary terminal screws
4. Insert red wire into the power terminal
5. Insert black wire into the common terminal
6. Insert white wire into the appropriate station terminal
note: If installing more than one motion sensor, multiple power
(red) wires will be inserted into the single power terminal. Multiple
common (black) wires will be inserted into the single common
terminal. White wires will be inserted into the appropriate station
terminal. For motion sensor to operate, start times, stop times, and
sensor times must be entered into your Lighting Controller.
.
7. Secure the wires by tightening the screws.
WarningS:
• The main low voltage cable is intended for shallow burial—less than 6 inches
(152 mm).
• Warning—Risk of Electric Shock. Install all luminaries 10 feet (3.05 m) or
more from a pool, spa, or fountain.
• Landscape lights by Hydro-Rain
®
do not use tungsten halogen bulbs unless
marked for such.
• Protect your low voltage cable by:
• Routing it in close proximity to the light or fitting
• Routing it next to a building structure (e.g. house, deck)
D i
• Do not bury deeper than 6 inches (15.2 cm) in order to connect to the main
low voltage cable
• Trim the cable length so that it is attached to a connector within 6 inches
(15.2 cm) from a building structure, a landscape light, or a fitting.
Help:
www.hydrorain.com
.
Before returning this controller to your authorized Hydro-Rain
contact Hydro-Rain Technical Service at: 1-888-493-7672.
WarrantY and StateMent:
Hydro-Rain
materials and workmanship for a period of five years from the date of purchase.
We will replace, free of charge, the defective part or parts found to be defective
STATION
MOTION SENSOR
LIGHT
SENSOR
COM
1
2
3
PWR COM
1
2
3
under normal use and service for a period of up to five years after purchase
(proof of purchase required).
Hydro-Rain
White
Red wire
wire
Hydro-Rain
damage caused by the product failure.
Black wire
Hydro-Rain
repair of defective parts.
To exercise your warranty, return the unit to your authorized distributor with a
copy of the sales receipt.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that
may cause undesired operation.
Warning: Changes or modifications to this unit not expressly approved by the
party responsible for compliance could void the user's authority to operate the
equipment.
Hydro-Rain
®
915 Overland Street
North Salt Lake, UT 84054 USA
www.hydrorain.com
1-888-493-7672
distributor,
®
®
warrants to its customers that its products will be free from defects in
®
reserves the right to inspect the defective part prior to replacement.
®
will not be responsible for consequential or incidental cost or
liability under this warranty is limited solely to the replacement or
®
PN 06730-24 rA
loading

Resumen de contenidos para HYDRO-RAIN HRL-100-MS

  • Página 1 Motion SenSor inStruction Manual 0 " 3. Install a screw into the lower pre-formed hole (15.2 cm) from a building structure, a landscape light, or a fitting. Congratulations on selecting your new Landscape before doing the same with the upper pre-formed Help: Lighting Motion Sensor. The HRL-100-MS (part number: hole 06730) connects directly into the Hydro-Rain ® 3-Station LED 4. Adjust the sensor head to further optimize motion www.hydrorain.com...
  • Página 2 3 estaciones para brindar mayor seguridad, confort y en un lugar que esté más allá del largo de su cable www.hydrorain.com belleza a su hogar y el patio. (aproximadamente 8 pies [2.4 m]). Antes de devolver este controlador al distribuidor autorizado Hydro-Rain ® caracteríSticaS del SenSor de MoviMiento: comuníquese con el Servicio Técnico de Hydro-Rain al: 1-888-493-7672. conexión del sensor de movimiento al terminal: • Sensor de movimiento infrarrojo pasivo...