Gas Requirements; Gas Supply - GE PTD60GBPRDG Instrucciones De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

CONNECTING A GAS DRYER (cont.)

GAS REQUIREMENTS

WARNING
• Use a new CSA International approved flexible
gas supply line. Never reuse old flexible
connectors.
• Install an individual manual shut-off valve
within 6ft. of the dryer in accordance with the
National Fuel Gas Code, ANSI Z223.1/NFPA
54.
• Securely tighten all gas connections.
• If connected to LP gas, have a qualified
person make sure gas pressure DOES NOT
exceed 13" (33 cm) water column.
• Examples of a qualified person include:
licensed heating personnel, authorized gas
company personnel, and authorized service
personnel.
• Failure to do so can result in death,
explosion, or fire.
• The installation must conform with local
codes, or in the absence of local codes, with
the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, or the Natural Gas and Propane
Installation Code, CSA B149.1.
DRYER GAS SUPPLY CONNECTION
1-7/8"
3-1/8"
3/8" NPT MALE THREAD GAS SUPPLY
NOTE: Add to vertical dimension
the distance between cabinet
bottom to floor.
You must use with this dryer a flexible metal connector
(listed connector ANSI Z21.24 / CSA 6.10). The length
of the connect shall not exceed 4 ft. (1.2 m).
Installation Instructions
- Explosion Hazard

GAS SUPPLY

• A 1/8" (3.2 mm) National Pipe Taper thread
plugged tapping, accessible for test gauge
connection, must be installed immediately
upstream of the gas supply connection to the
dryer. Contact your local gas utility should you
have questions on the installation of the plugged
tapping.
• Supply line is to be 1/2" (12.7 mm) rigid pipe and
equipped with an accessible shutoff within 6 feet
(1.8 m) of, and in the same room with, the dryer.
• Use pipe thread compound appropriate for
natural or LP gas or use PTFE tape.
• Connect flexible metal connector to dryer and
gas supply.
WARNING
FOR USE WITH NATURAL GAS ONLY
Dryer as produced by manufacturer is to be used
only with a natural gas supply. A manufacturer-
supplied conversion kit is required to convert this
dryer for propane gas supply. Use propane gas
conversion kit WE25M87. Conversion must be
made by properly trained and qualified personnel
in accordance with local codes and ordinances.
ADJUSTING FOR ELEVATION
• Gas clothes dryers input ratings are based on
sea level operation and need not be adjusted for
operation at or below 2000 ft. (610 m) elevation.
For operation at elevations above 2000 ft. (610 m),
input ratings should be reduced at a rate of 4
percent for each 1000 ft. (305 m) above sea level.
• Installation must conform to local codes and
ordinances or, in their absence, the NATIONAL
FUEL GAS CODE, ANSI Z223.
5
- Fire Hazard
Tabla de contenido
loading

Tabla de contenido