1. Set the function switch to position F
2. Connect the transistor adapter to terminal COM and to terminal
3. Completely discharge the capacitor to be measured, then plug it into the adapter
4. Read the value displayed on screen once it has stabilised
1. Set the function switch to position hFE
2. Connect the transistor adapter to terminal COM and to terminal
3. Connect the transistor into the appropriate holes of the adapter depending on the
type of NPN or PNP transistor
4. Read the value displayed on screen once it has stabilised
1. Connect the black probe to terminal COM and the red probe to terminal
2. Set the function switch to position
3. Connect the test plungers to the diode :
(A) Test in the direct direction: connect the black plunger to the cathode and the red
plunger to the anode, measuring the voltage in the direction of a normal diode; the
screen will display 0.5 to 0.7V and the blocked direction will display "1".
(B) Test in the opposite direction: connect the black plunger to the anode and the
red plunger to the cathode. The diode is good if the display shows "1".
1. Connect the black probe to terminal COM and the red probe to terminal
2. Set the function switch to position
3. Connect the test plungers to the circuit and if the resistance is < 30Ω, the audible
signal will sound and the display shows
1. Set the function switch to position NCV
2. Move the tester closer to the area to be tested. When it detects an AC voltage, the
buzzer sounds and a red light comes on.
.
mAΩ