Airtemp B6Q10F2A Manual De Instalación Y Operación página 7

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Directing Airflow
Unit is engineered with adjustable louvers to direct discharge airflow. Louvers
are manually adjusted by moving levers in direction of desired airflow (Fig. 10).
Cleaning Air Filter
Clean the filter every two weeks
1. Turn unit OFF.
2. Remove the air filter by grasping the top corners and pulling it up and out
of the unit (Fig. 10).
3. Wash in hot soapy water, rinse and shake dry.
4. Replace the filter, with the front of the filter toward you.
5. To dry the filter thoroughly, run your unit for a few minutes. Remember,
only a clean filter works properly and delivers top performance.
Service Instructions
To save time and expense, check the following before calling an authorized service com-
pany.
Insufficient Cooling
p Shut all windows and doors in room.
p Remove any obstructions from inside and outside cabinet louvers.
p Close Vent Door (available on most models).
p Inspect filter and clean if dirty.
p Turn Thermostat and Mode to coolest settings.
Under certain conditions the cooling coils directly behind the filter, may ice up
and block the airflow. This is a common occurrence in air conditioners caused
when the outside temperature drops below 70°F (21°C) while the humidity
remains high. If this happens, simply turn the unit off and allow the ice to melt,
then resume normal operation.
Insufficient Heating (Heating Models Only)
p Shut all windows and doors in room.
p Remove any obstructions from inside and
outside cabinet louvers.
p Close Vent.
Unit Fails to Start
Replug line cord plug into outlet to be sure electrical contact is being made.
p
(If firm contact is not being made, outlet may have to be replaced).
Turn Master Control to HI FAN. If air circulating fan does not operate, check
p
house circuit breaker (or fuses).
All manuals and user guides at all-guides.com
7
10
Air filter
Proper use and care of your air conditioner will help ensure longer life of the
unit. It is recommended to annually inspect and clean the coils and condensate
water passages. Expense of annual inspection is the consumers' responsibility.
Note: Failure to keep air filter clean will result in poor air cir-
culation.
DO NOT operate without filter. This can render the unit inop-
erative.
SERVICE
TROUBLESHOOTING
Adjustable louvers
Tabla de contenido