Installation manual
blueChip Reader BC TI and BC TE
blueSmart Reader BS TI and BS TE
Installation instructions
Technical data and pin configuration
If several readers are being installed, then a
Supply voltage at V1 and V2:
minimum distance of at least 20 cm must
be maintained between readers. If induc-
Relay connection NO
tive loads are switched, then a quenching
diode must be installed parallel to the load
Relay connection NC
Relay connection COM
for protecting the contacts. If the supplied
cable is shortened or lengthened, then the
Switching current/
switching voltage max.:
reading range of the reader may be nega-
tively influenced. Grounding adapter be-
Power consumption at 12 V DC:
Protection class:
tween potential earth (PE) and V1 or V2 for
protection from extraordinarily high inter-
Temperature range:
ference voltage. Connection to a higher volt-
age will cause the destruction of the reader.
It is recommended to use a regulated power
Reading interval with key:
supply, which provides an output voltage
Reading interval with card:
of 12V. In a voltage-free condition of the
Assembly:
reader, no contact exists between „NC" and
„COM". If an authorised key is held in front
of the reader for more than three seconds,
then a continuous release is activated.
Wiring Bx TE
Antenna unit of Bx TE
Only with readers that have a separated antenna
Buzzer
ON-
ON+
GND
LDR
LDG
SUM
Cable length 3.0 m, 3 pairs, stranded
All manuals and user guides at all-guides.com
8 V bis 16 V DC oder AC 50 Hz
(low power source max. 8 A; max. 100VA)
= normal open, operating side
= normal closed, non-operating side
= common, middle pin
1 A/30 V
80 mA
Siedle: IP 54
Gira and bticino: IP 20
Bx TE antenna unit: -25 °C to +60 °C,
Control unit: -10 °C to +55 °C
Bx TI: -10 °C to +55 °C
typically 10 mm
typically 40 mm
preferably in standard flush mounted box (UP55)
or surface-mounted box combined with a suitable
switch design ( e. g. Gira, Siedle, bticino)
Control unit Bx TE
Connection on direct-current (DC)
or alternating-current (AC)
grey lead
11
Power V1
pink lead
1
12
Power V2
white lead
Relay
2
13
Relay
NO
brown lead
3
14
Relay
NC
green lead
4
15
Relay
COM
yellow lead
5
16
Contact shown in the open position
grounding adapter
Wiring Bx TI
L
230 V AC
12 V AC
MP
ground
Reader Bx TI
grounding adapter
Buzzer
Power V1
1
Power V2
Relay
2
Relay
3
Relay
4
Relay
5
Contact shown in the open position
Bx TI/TE: LED and buzzer signals
Description
Display of system status
Normal state, continuous release inactive
Normal state, continuous release active
Behaviour in the event of a normal state entry
Authorised key
Unauthorised key
Authorised key (continuous release active)
Unauthorised key (continuous release active)
Activation of continuous release
Deactivation of continuous release
(Red LED blinks along with a buzzer signal, after that yellow LED blinks)
Display of an error condition
This condition leads to the deactivation of the continuous release
Error clock time, continuous release inactive
Error time, continuous release active
Behaviour in the event of a transaction during an error state
Error
No transaction is possible in this state
Error time
Alternating with the signalling of a normal transaction
Behaviour during a programming procedure
AC / = DC
3 ms yellow LED signal after each received data frame
AC / = DC
= LED on
= LED blinks
ground
Aug. Winkhaus GmbH & Co. KG declares herewith that the device is compliant with the basic requirements and the relevant rules in
directive 2014/53/EU. The long version of the declaration of EU confirmity is available at:
www.winkhaus.com/konformitaetserklaerungen
L
230 V AC
12 V AC
MP
ground
grounding adapter
Power V1
Power V2
NO
Relay
NO
NC
Relay
NC
COM
Relay
COM
recovery diode
door opener
bipolar
12 V AC
Green LED
Reader Bx TI
Wiring during closed-circuit
operation
recovery diode
door opener
bipolar
12 V AC
Red LED
Yellow LED
Buzzer
200 ms
750 ms
12 ms
12 ms
2 x 200 ms
2 x 750 ms
10 x 50 ms