2. See
Figure
4-6. Loosen nuts (A) and ten-
sioning bolt (B).
Figure 4-6. Loosen Nuts
3. See
Figure
4-7. Push pump toward engine.
Figure 4-7. Push Pump Toward Engine
4. Remove old belt and install new belt.
5. See
Figure
4-8. Pull pump away from
engine so bolt is approximately 2/3 of the
way through the pump bracket slot (A).
Tighten bolt.
Figure 4-8. Pull Pump Away From Engine
6. See
Figure
4-6. Tighten tensioning bolt (B).
The pulleys should be aligned within 1° of
each other and the new belt should be ten-
sioned to ~90.5 lbs. (1/8" deflection under
8.3 lbs. with a tension gauge).
7. See
Figure
4-6. Tighten all four nuts (A).
8. Replace belt guard before running unit.
Owner's Manual for Power Washer
B
A
A
Engine Maintenance
Engine Oil Recommendations
Only high-quality detergent oils classified for
service SF, SG, SH, SJ or higher are recom-
mended. DO NOT use special additives.
Climate determines proper engine oil viscos-
ity. See chart to select correct viscosity.
000272
* Below 50°F (10°C) use of SAE 30 will result
in hard start.
** Above 80°F (27°C) use of 10W30 may
cause increased oil consumption. Inspect oil
level more frequently.
000273
Inspect Engine Oil Level
Inspect engine oil level prior to each use, or
every 8 hours of operation.
1. Place power washer on a level surface.
2. Clean area around oil fill.
3. See
Figure 4-10
wipe dipstick clean.
000274
4. Screw dipstick into filler neck. Verify
proper oil level on dipstick.
10W-30**
5W-30
Figure 4-9. Oil Viscosity
Remove oil fill cap and
Figure 4-10. Engine Oil Fill
Figure 4-11. Oil Level
SAE 30*
000130
000115
000116
13