Blue Lagoon AOP COMPACT OZONE & UV-C 75W 2.0 Manual De Instrucciones página 29

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
The UV-C lamp should never be
turned on when there's no flow.
At a high concentration, ozone can be
toxic. Smog caused by ozone can damage
OZON
the lungs and mucous membranes of
humans and animals. Inhalation can
cause illness. Smellable ozone should
be considered as high concentration.
GROUNDING INSTALLATION (FIGURE 22)
1. Before the plastic strain relief (4) is fitted on the earthing bolt (1), first pull the cable (2) through the strain
relief (4). Place the strain relief (4) about 10 cm from the eye (2) of the earthing cable.
2. Place the eye (2) of the cable over the earthing bolt that is attached to the housing.
3. Then place a serrated lock washer (3).
4. Attach the strain relief (4) to create a Ø5 cm loop.
5. Finally, place the second serrated lock washer (5) and the lock nut (6) on the earthing bolt.
6. Once the parts have been placed on the earthing bolt in the correct order, it can be tightened with an
8 mm open-end or ring spanner.
INSTALLATION OF THE DEVICE (SEE DRAWING 3)
Decide where you want to mount the device. Never install the UV-C unit after the pH controller, chlorine
dispenser or salt electrolysis system in the swimming pool installation. The best place to install the device is
directly after the filter. See the schematic diagram in the operating instructions. Make sure there is always water
flowing through the device when the lamp is on. Never install the device in direct sunlight. Install the device in
a dry, well-ventilated area. The device can be installed either horizontally or vertically, provided that the water
flow is from bottom to top (see schematic diagram at the beginning of the instructions for use), with 30 cm of
unobstructed space on the side opposite of the lamp connection for future maintenance. At least one metre of
unobstructed space must be left on the side with the lamp connection for convenient future replacement of
the lamp (K) without having to disconnect the entire device.
ATTENTION: all connections and couplings must be hand tight, without tools. This is to prevent
damage.
1. Remove the nut (X1) from the bottom of the reactor (Figure 1).
2. Place the nut (X1) over the venturi's outlet. Glue the adapter (K1) in the glue coupling (J1) with
the thread side first. Then glue the venturi (A) to the adapter with glue coupling. Allow the
glued objects to evaporate for 8 hours (picture 2).
3. Check if the O-ring (W1) is still in the unit. Mount the venturi system at the bottom entrance of
the reactor (Figure 3).
4. Unscrew the nut (X2) from the top of the reactor, on the side you want to use as an exit.. Attach
the glue coupling (J2) to the top of the reactor, then tighten the nut (X2) again. Cap the other
side by loosening the nut (X2), place the blind plate (R) On the reactor and screw back the nut
(X2). (Figure 4).
UV-C and Pool equipment
Wear safety glasses during
maintenance and installation.
AOP COMPACT OZONE & UV-C 75W 2.0 |
EN
29
Tabla de contenido
loading

Tabla de contenido