Temperature Calibration; Clock Setting - koban KCT19 Manual De Instrucciones

Termostato con pantalla táctil
Idiomas disponibles

Idiomas disponibles

Span Selection
"P" represents span setting, the temperature hysteresis
when demand is met or demand is fulfilled.
selectable values are 0.5°C(1°F) / 1.0°C(2°F) / 1.5°C(3°F).
Smaller value will result in faster heating/cooling response
but more system cycling.
Bigger value will result is
slower system response and less system cycling.
o
o
default span setting is 0.5
C / 1
F.
Press
/
to change the values. Press CONFM to
apply changes and proceed to the next setting.

Temperature Calibration

This thermostat is calibrated at factory, calibration is
generally not needed. However if calibration is desired,
p ress
/
to offset the temperature measurement.
The range of offset is
3.0 to +3.0°C /
6.0 to +6.0°F.
-
-
Short/Long Delay Selection
Press
/
to select between short or long minimum
.
off time for heat
This selection does not affect cooling.
Press CONFM to apply changes and proceed to next
setting.
Select Long minimum off time for compressor heat to
prevent short cycling of system ; Otherwise select Short
minimum off time for faster system response.
" SdLY" represents delay. "LdLY" represents long delay.
Delay
Long delay
Heat mode
5
10sec
4
5 min
-
-
Cool mode
4 - 5 min
4 - 5 min
DST (Daylight Saving Time)
Press
/
to enable/disable DST (summer time)
The
function. The clock will advance or retreat automatically
on the switch days. DST begins on the last Sunday in
March and ends on the last Sunday in October.
The
Time switching will be carried out at Central European
Time 2am. When the clock is advanced, DST icon will be
shown on screen.
If your region is outside Central
European Time, DST switch time may differ by a few
hours but time will match afterwards. Alternatively, DST
feature may be disabled and clock shall be adjusted
manually.
4
Screen Lock Selection
Press
or
to enable (ON) or disable (OFF) the
security lock. If it is enabled, user is required to input a
-digit password.
Press
or
on the left to change the password. P1
st
indicates that the 1
digit password (read from the left) is
selected. Press
or
on the right to select the digit.
After setting all 4 digits, press CONFM to activate the
security mode. Do not set the password as 8888, 8888 is
a special function to restore all thermostat setting to
Please keep the pa ssword in a safe location,
default.
there is no way to disable the screen lock until a correct
password is entered.
When security mode is activated, " " is shown on the
LCD and all keys are disabled excep t SYSTEM.
Disable the Screen L ock
1. Press SYSTEM and enter th e correct password .
2. If the password is correct, the security lock will be
disabled. Otherwise, it remains locked.
View Calendar
1. Press the current weekday to view the current date.
2. Press EXIT to exit.

Clock Setting

(Normally clock adjustment is not needed . Thermostat
will retrieve the time automatically when it is configured
to online.
Time zone setting must be adjusted
accordingly.)
1. Press CLOCK to enter the clock setting mode.
2. When thermostat is online:
 Press
or
to adjust the Time zone
(Greenwich Mean Time) setting (-12 to +13 hours).
Press CONFM to save the setting.
When thermostat is offline:
 Hour adjustment screen is shown. Press
to change the hour. Press CONFM to save the
or
TEMPER ENERGY INTERNATIONAL S.L.
Polígono industrial de Granda, nave 18
33199 • Granda - Siero • Asturias
Télé phone: (+34) 902 201 292
Fax: (+34) 902 201 303
www.grupotemper.com
1412 11
loading

Este manual también es adecuado para:

0769019