BEFORE INSTALLING:
All installations should comply with National and local Electrical
codes.
If you have any doubts concerning installation contact a quali-
fied licensed electrician.
CAUTION:
To reduce the risk of fire, do not install closer than 1 inch to cabinet
wall or in compartment smaller than 12 inches by 12 inches by
12 inches.
IMPORTANT SAFETY INSTRUCTIONS
a)
Read all instructions
b)
Do not conceal or extend exposed conductors through
a building wall, floor or ceiling
c)
Install this system in dry or damp locations only
d)
To reduce risk of fire and burns, do not install this lighting
system where the exposed bare conductors can be
shorted or contact any conductive materials
e)
To reduce the risk of fire and overheating, make sure all
connections are tight
f)
Do not install any luminaire closer than 6 inches (15.25cm)
from any curtain, or similar combustible materials
g)
Power supply has two distinct sections for line voltage
(AC Input) and low voltage (DC Output). It is important
to keep the line voltage and the low voltage wires separate.
h)
Turn off electrical power before modifying the lighting
system in any way
MOUNTING SCREW
NOTE: Kichler 6TL-Series (24V) and 4TL-Series
(12V) Power Supplies are not compatible with
dimmers when used in conjunction with tape
light controllers.
Date Issued: 12/4/15
Kichler 6TL-Series (24V) and 4TL-Series (12V) Power Supplies
Installation Instructions
120V TERMINAL BLOCK
We're here to help
SAVE THESE INSTRUCTIONS
1)
Turn off power
2)
Determine desired location for mounting power supply. Power
supply should be located within 25' of first luminaire.
3)
Secure power supply using provided mounting screws.
Secure into wall studs if possible, otherwise, use appropriate
anchors rated for proper wall material and hanging weight
(not included).
4)
Using the pre-punched knock-outs in the metal enclosure,
route and connect the 120V line voltage to the primary side
(AC Input) of the power supply.
NOTE: Connect 120V line wire to terminal location marked
"L", connect 120V neutral line to wire marked "N" and connect
ground wire to terminal marked with ground (
screws to ensure wires are secured.
NOTE: A proper UL listed cable connector must be used in
the knock-outs to provide strain relief and wire protection.
5)
Total load of the installed lighting system must not exceed
rated Wattage of power supply.
NOTE: After determining the layout of the system, add the
wattage of each luminaire/fixture together to calculate the
total system consumption. The calculated total system
consumption should be equal or less than the Class 2 power
supply rating that is being used.
6)
Using the pre-punched knock-outs in the metal enclosure,
route and connect the lighting system leads to the secondary
side (DC Output) of the power supply.
NOTE: Connect positive to the red wire and negative to the
black wire using the supplied wire nuts or other UL ap
proved connectors.
NOTE: A proper UL listed cable connector must be used in
the knock-outs to provide wire protection.
THIS DEVICE COMPLIES WITH PART 15 OF THE
FCC RULES. OPERATION IS SUBJECT TO THE
FOLLOWING TWO CONDITIONS: (1) THIS DE-
VICE MAY NOT CAUSE HARMFUL INTERFER-
ANCE, AND (2) THIS DEVICE MUST ACCEPT
ANY INTERFERANCE RECEIVED, INCLUDING
INTERFERANCE THAT MAY CAUSE UNDESIRED
OPERATION.
866-558-5706
Hrs: M-F 9am to 5pm EST
). Tighten
LOW VOLTAGE WIRE
COMPARTMENT
IS-6TD24V6-US