PDS-1800-E
PDS-1805-E
Serial #:
Your Electronic Safe Combination:
Battery Disposal
Please dispose the used batteries
per municipal or provincial law.
PDS-1800-E Hardware Included:
(2) M6 x 15 mm (5/8" long) Screws
(2) M6 Nylock Nuts
PDS-1805-E Hardware Included:
(4) M6 x 50 mm (2" long) Lag Screws
(4) M6 x 40 mm (1-1/2" long) Plastic Masonry Anchors
(4) M4 x 25 mm (1" long) Screws
(4) Washers
(4) Drywall Anchors
Tools Required:
Drill
Thin Bladed Flat Head Screwdriver
Phillips Screwdriver
10 mm Wrench
1/4" (7 mm) Drill Bit
*3/8" (9.5 mm) Masonry Brill Bit for drilling into masonry
*3/16" (5 mm) Drill Bit for drilling into wood and wall studs
* For model PDS-1805-E only
®
Instructions
IMPORTANT
Record the serial number from the tag on the back
of the safe or the tag on the inside of the lock cover
plate on the front of the safe.
Record your combination number.
Keep keys and combination in a secure place away
from children.
DO NOT STORE KEYS OR YOUR COMBINATION
INSIDE SAFE
GETTING STARTED
When you first receive your new electronic safe
you will need to open the door with the key in
order to install the batteries. Batteries are
included and are located inside the safe.
To open the door with the key, first remove
the lock cover from the front of the faceplate
using a thin bladed flathead screwdriver as
shown. Insert the key and turn
counterclockwise. Hold the key in the open
position and turn the knob to the right to
open the door.
NOTE: The key has also been provided in case
you lose or forget your security code or the
batteries run low. If you lose your key, you
may purchase a replacement key by
referencing the serial number located under
the removable lock cover. See section at the
end of this instruction regarding
replacement keys.
Locate the batteries inside the safe. Open the
battery compartment on the back of the door
by pushing the tab in the direction of the arrow
and install the batteries.
LOCK COVER
1
40791-1802
12
Tabla de contenido
loading

Resumen de contenidos para STACK-ON PDS-1800-E

  • Página 1 Battery Disposal LOCK COVER Please dispose the used batteries per municipal or provincial law. PDS-1800-E Hardware Included: (2) M6 x 15 mm (5/8” long) Screws (2) M6 Nylock Nuts NOTE: The key has also been provided in case PDS-1805-E Hardware Included: you lose or forget your security code or the (4) M6 x 50 mm (2”...
  • Página 2 If an incorrect security code is entered 3 times NOTE: The reset button located on the inside of the door, is covered with a the light will flash red 5X and beep 5X (if the sound is turned on) then alarm will sound for removable cap.
  • Página 3: Battery Replacement

    NOTE: Do not mix old and new batteries. NOTE: This safe must be mounted into a Do not mix alkaline, standard or drawer (PDS-1800-E) or into a drawer or the rechargeable batteries. wall (PDS-1805-E). Failure to do so will compromise the safety and security of the safe.
  • Página 4: Wall Mounting

    To order a replacement key set, follow the instructions on the attached form. FIGURE 2 STACK-ON PRODUCTS CO. P.O. BOX 489, WAUCONDA, IL 60084 © 2018 STACK-ON PRODUCTS 40791-1802...
  • Página 5 In order to receive a replacement Key or Combination or RFID devices for your security product: 1. Please visit the following link: https//www.stack-on.com/customer-service/ 2. Locate and click on the "Replace your lost keys/combination" icon 3. Follow the Instructions provided to receive your key, combination, or RFID devices...
  • Página 6 LIMITED THREE YEAR WARRANTY STEEL SAFES Stack-On Products Co. (“Stack-On”) Steel Safes are warranted to be free from defects in material and workmanship for a period of three (3) years from the date of original purchase by a consumer. This warranty extends to the initial consumer only.
  • Página 7: Para Comenzar

    ® de atrás de la caja fuerte o de la etiqueta ubicada adentro de la tapa de la cerradura en la parte de enfrente de la unidad. PDS-1800-E Registre los números de combinación. Instrucciones PDS-1805-E Guarde las llaves y la combinación en un lugar seguro y fuera del alcance de los niños.
  • Página 8: Programación De Su Número De Seguridad

    NOTA: El botón de reinicio situado en el interior Si se ingresa un código de seguridad incorrecto 3 de la puerta, se cubre con una tapa extraíble. veces, la luz parpadeará en rojo 5X y emitirá un Cuando se utiliza el botón de reinicio mientras el pitido 5X (si el sonido está...
  • Página 9: Reemplazo De Las Pilas

    SELECCIÓN DE LA UBICACIÓN Este seguro debe estar montado en un cajón NOTA: No mezcle pilas viejas y nuevas. No mezcle (PDS-1800-E) o en un cajón o en la pared pilas alcalinas, pilas estándar o recargables. (PDS-1805-E). Para la seguridad y protección óptima, la caja fuerte se debe instalar en una...
  • Página 10: Montaje En La Pared

    Para pedir una llave de recambio, siga las instrucciones en el formulario adjunto. Figure 2 STACK-ON PRODUCTS CO. P.O. BOX 489, WAUCONDA, IL 60084 © 2018 STACK-ON PRODUCTS 40791-1802...
  • Página 11 Para recibir una Llave de Repuesto o Combinación o Dispositivo RFID para su producto de seguridad: 1. Favor visite el siguiente enlace: https//www.stack-on.com/customer-service/ 2. Encuentre y haga clic sobre el icono para reponer sus llaves/combinación extraviados ("Replace your lost keys/combination") 3.
  • Página 12 En caso que Stack-On sea notificado debidamente dentro del periodo de tres años de la garantía, y la inspección posterior verifica que existe un defecto, a su discreción exclusiva, Stack-On proveerá piezas de repuesto o intercambiará...

Este manual también es adecuado para:

Pds-1805-e

Tabla de contenido