SIMPLIFIED MANUAL
DONA WIFI - OUTLETS
DESCRIPTION
The Dona WiFi outlets module aims to control a power load (eg outlets, motors, heating,
etc.) in a simple and efficient way. This module is easy to install and can be used without
changing the existing electrical installation. This module is intended to be placed in the
electric box behind an outlet or alternatively, if it facilitates installation, in the junction
box responsible for the circuit to be controlled. This system, besides allowing to control a
power circuit, also has two inputs. A digital input allowing the connection of a pressure
switch or position such as sensors with on-off output (eg generic motion sensors). The
second input is an analog input, with a reading range of 0V to 10V, and can be associated
with any analog output sensor within this range of values.
INSTALLATION
Please read the manual before starting the installation. For more detailed instructions
please visit our website https://dona.life.
Make sure that the circuit breaker is turned off before starting the installation.
1.1 Switch off the outlets circuit in the main circuit breaker;
1.2 Check that the outlet has no power;
1.3 Open the outlet;
1.4 Check the connections in the installation area. Separate the neutral and the hot wire
to the module power source.
2. Connect the hot and neutral wires to the points L and N;
3. Connect the relay output being point C the common of the relay and the points NO the
normally open contact and NC the normally closed contact;
4. If you want to configure a sensor and/or a switch, connect the black wire (G) to the
common point of the switch and the yellow wire (I1) to the switch or/and the red wire (A1)
to the sensor;
5. Insert back the oulter, its plate and tighten the screws;
6. Access the DPU and configure the module.
Caption
C - Common
NO - Norm. Open
NC - Norm. Closed
L - Phase Line
N - Neutral Line
I1 - Yellow wire
G - Black Wire
A1 - Red Wire
Figure 1
CONFIGURATION
- Access the "DW_Outlet_xxxxxx" Wi-FI network that is written on the product
label with password "donawifi". Access directly through the url 192.168.4.1;
- Insert the the SSID and password of your home Wi-Fi network;
- Access your DPU and configure the module.
FACTORY RESTORE
1.Turn on/off the module power source;
2. Press 12 times the switch associated with I1 digital input.
TECHNICAL SPECIFICATIONS
ENVIRONMENT
Temperature
POWER
Power consumption
Power source
SECURITY
Classification
INPUTS AND OUTPUTS
1 analog input 0-10V
1 digital input
1 relay output - current rating 16A
DIMENSIONS
Box
Weight
SAFETY INSTRUCTIONS
1. Do not install near heat sources;
2. Do not remove the module from its box;
3. If the installation does not follow this instructions, safety and the normal
operation of the system may be compromised.
WARRANTY TERMS AND CONDITIONS
Dona products have a 2 years (24 months) warranty period and the invoice
should be kept for this purpose.
Warranty rights will not apply if the product is damaged by misuse, including
surface damage such as scratches, cuts, rips and changes to the labels
Figure 2
surrounding the product or deformations.
For more information read the eligibility and warranty conditions available
on our website https://dona.life .
Dona . Smart Home
www.dona.life
EN
5 a 60ºC
1,5 W
110 - 230VAC
IP20
l50mm x w51mm x h25mm
≈ 100g
MS-DWOUTLT-004
18-09-2019
Developed by Winwel Electronics
Praça da Faculdade de Filosofia, N 14
4710-297 Braga, Portugal
www.winwel.com