Choice of the location
1.1
Recommended positions
Fig.13
Recommended positions for the outside sensor
2
1
Z
1/2 Z
1 Recommended position
2 Possible position
1.2
Positions to be avoided
Fig.14
Positions to be avoided for the outside sensor
94863059 - v3 - 23012017
Place the outside sensor in a position that covers the following character
istics:
2
1
H
1/2 H (min. 2,5 m)
Avoid placing the outside sensor in a position with the following character
istics:
On a façade of the area to be heated, on the north if possible.
Half way up the wall of the area to be heated.
Under the influence of changes in the weather.
Protected from direct sunlight.
Easy to access.
1/2 H (min. 2,5 m)
H
H Inhabited height controlled by the sensor
Z Inhabited area controlled by the sensor
Masked by part of the building (balcony, roof, etc.).
Close to a disruptive heat source (sun, chimney, ventilation grid, etc.).