eNet
Actuador pulsador/de conmutación 8 fases / actuador persianas 4 fases
eNet, carril DIN
Operating mode
Local Operation
Manual switch-off of the run-
on time
82581923
J0082581923
Switching operation
Push-button operation
Flashing
Continuous on
Continuous off
Basic setting: Switching ope-
ration
On, Off
Basic setting: On
On, Off
Basic setting: Off
11/17
Switching operation
After switch-on, the device re-
mains stable in the "On" state,
and stable in the "Off" state af-
ter switch-off.
Push-button operation
The device switches "On"
when any channel button of a
radio transmitter is pressed
and "Off" when the button is
released. It is irrelevant whet-
her the "On" or "Off" channel
button is pressed.
Flashing
Switch-on starts flashing and
switch-off stops flashing. The
default flash frequency is 1
Hz. This frequency is also the
maximum flash frequency.
The flash frequency can be
changed using parameters.
The parameter "Switch-off de-
lay" is used for the pulse time
and the parameter "Switch-on
delay" for the pause time.
Continuous on
The output switches to conti-
nuously "On". All operations of
radio transmitters and the
Prog button are ignored.
Continuous off
The output switches to conti-
nuously "Off". All operations of
radio transmitters and the
Prog button are ignored.
Blocks the output for operation
using the Prog button.
Allows manual switch-off of a
running run-on time. If the pa-
rameter is switched off, then a
switch-off command will also
switch the actuator on. This
parameter is directly connec-
ted to the "Run-on time" para-
meter.
22.07.2016