EN
OPERATING AND MAINTENANCE INSTRUCTIONS FOR MAGNEX LINE
PREFACE
You have purchased a CROSBY lifting magnet. We thank you
for the trust you have placed in our product. These instructions
contain all the information required for safe and optimum
use of the lifting magnet. Read the instructions carefully and
follow the directions. Keep the instructions in a safe place
close to the workplace.
On delivery check that the magnet is undamaged and complete.
If the equipment is damaged or incomplete contact your
supplier immediately.
NEVER USE A DAMAGED OR INCOMPLETE MAGNET!
MAGNEX are guaranteed for a term of 60 months on the magnetic system from the time of purchase. The guarantee is not
applicable to shortcomings that can be wholly or partially attributed to:
+
failure to comply with the operating and maintenance instructions or use considered as being other than normal
+
normal wear
+
modification or repairs not performed by CROSBY or authorised agent
In all correspondence regarding your lifting magnet always state the information displayed on the type plate.
TYPE
length (mm)
width (mm)
height incl. lifting eye (mm)
weight (kg)
min. tested lifting capacity (kg)
0,1 mm AIR GAP
workload limit for plates (kg)
minimum plate thickness (mm)
workload limit pipe and tube (kg)
Ø min/max (mm)
150
93
60
123
3,1
450
150
25
75
50/95
62/197
3
2
1
4
5
6
THE COMPLETE DELIVERY CONSISTS OF
300
600
152
246
100
120
180
188
10,9
21,7
900
1800
300
600
30
30
150
300
62/265
NAMES OF THE MOST IMPORTANT PARTS OF THE
LIFTING MAGNET
1.
Magnet
2.
Instruction plate + type plate
3.
Lifting eye
4.
Handle
5.
Handle lock plate
6.
Pole shoes
MAGNEX MAGNET
OPERATING AND
MAINTENANCE INSTRUCTIONS
INCL. EU DECLARATION
OF CONFORMITY
TEST CERTIFICATION
1000
1500
305,5
381
146
165
241
285
40,9
71,7
3000
4500
1000
1500
60
80
500
750
62/299
81/309
2000
488
165
285
91,4
6000
2000
80
1000
81/309