Model(s):
FM56AH U34 (MJ09PC NSJ*2 + MJ18PC NSK*2)
Outdoor side heat exchanger of air conditioner: air
Indoor side heat exchanger of air conditioner: air
Type: compressor driven vapour compression
If applicable: driver of compressor: electric motor
Item
Symbol
Rated cooling capacity
P
rated,c
Declared cooling capacity for part load at given outdoor temperatures Tj
and indoor 27°/19 °C (dry/wet bulb)
Tj = + 35 °C
P
dc
Tj = + 30 °C
P
dc
Tj = + 25 °C
P
dc
Tj = + 20 °C
P
dc
Degradation co-efficient
C
dc
for air conditioners (*)
Off mode
P
OFF
Thermostat-off mode
P
TO
Capacity control
Sound power level, (Indoors)/outdoors
L
WA
If engine driven:
NOx (**)
Emissions of nitrogen oxides
Name : Christianna Papazahariou
Position : European Regulatory Manager
Contact details
Postal address : Paris Nord II – 117 avenue des Nations BP 59372
Villepinte – 95942 Roissy CDG Cedex
www.lg.com
(*) If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.
(**) From 26 September 2018. Where information relates to multi-split air conditioners, the test result and performance data may be obtained on the basis of the performance of the outdoor unit,
with a combination of indoor unit(s) recommended by the manufacturer or importer
Model(s):
FM56AH U34 (MJ09PC NSJ*2 + MJ18PC NSK*2)
Outdoor side heat exchanger of heat pump: air
Indoor side heat exchanger of heat pump: air
Indication if the heater is equipped with a supplementary heater: no
If applicable: driver of compressor: electric motor
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons are optional.
Item
Symbol
Rated heating capacity
P
rated,h
Declared heating capacity for part load at indoor temperature 20 °C
Tj = – 7 °C
P
dh
Tj = + 2 °C
P
dh
Tj = + 7 °C
P
dh
Tj = + 12 °C
P
dh
T
= bivalent temperature
P
biv
dh
T
= operation limit
P
OL
dh
For air-to-water heat pumps:
P
dh
Tj = – 15 °C (if TOL < – 20 °C)
Bivalent temperature
T
biv
Degradation co-efficient
C
dh
heat pumps(**)
Power consumption in modes other than 'active mode'
Power consumption in modes other than 'active mode'
Off mode
P
OFF
Thermostat-off mode
P
TO
Crankcase heater mode
P
CK
Capacity control
Sound power level, (indoors)/outdoors
L
WA
Emissions of nitrogen oxides
NOx(***)
(if applicable)
Name : Christianna Papazahariou
Position : European Regulatory Manager
Contact details
Postal address : Paris Nord II – 117 avenue des Nations BP 59372
Villepinte – 95942 Roissy CDG Cedex
www.lg.com
(*)
(**) If Cdh is not determined by measurement then the default degradation coefficient of heat pumps shall be 0,25.
(***) From 26 September 2018.
Where information relates to multi-split heat pumps, the test result and performance data may be obtained on the basis of the performance of the outdoor unit,
with a combination of indoor unit(s) recommended by the manufacturer or importer.
Information requirements for air-to-air air conditioners
Value
Unit
Item
15.50 kW
Seasonal space cooling energy efficiency
Declared energy efficiency ratio or gas utilisation efficiency
/auxiliary energy factor for part load at given outdoor temperatures Tj
15.50 kW
Tj = + 35 °C
11.42 kW
Tj = + 30 °C
7.34 kW
Tj = + 25 °C
3.70 kW
Tj = + 20 °C
0.25
Power consumption in modes other than active mode
0.022 kW
Crankcase heater mode
0.042 kW
Standby mode
Other items
For air-to-air air conditioner:
Variable
air flow rate, outdoor measured
(56/59)/73 dB
mg/kWh
x
fuel
GWP of the refrigerant
input GCV
Information requirements for heat pumps
Value
Unit
Item
17.40 kW
Seasonal space heating energy efficiency
Declared coefficient of performance or gas utilisation efficiency
8.40 kW
Tj = – 7 °C
5.12 kW
Tj = + 2 °C
3.29 kW
Tj = + 7 °C
2.90 kW
Tj = + 12 °C
9.50 kW
T
= bivalent temperature
biv
9.90 kW
T
= operation limit
OL
For water-to-air heat pumps:
x,x kW
Tj = – 15 °C (if TOL < – 20 °C)
For water-to-air heat pumps:
-10 ℃
Operation limit temperature
0.25
Back-up heating capacity(*)
0.022 kW
0.042 kW
Type of energy input
0.000 kW
Standby mode
Other Items
For air-to-air heat pumps:
Variable
air flow rate, outdoor measured
For water/brine-to-air heat pumps:
(59/62)/74 dB
Rated brine or water flow rate, outdoor side
heat exchanger
mg/kWh
x
GWP of the refrigerant
fuel
input GCV
Symbol
Value
Unit
η
273.0 %
S,C
EERd or
3.30
GUEc,bin/AEFc,bin
EERd or
5.07
GUEc,bin/AEFc,bin
EERd or
8.47
GUEc,bin/AEFc,bin
EERd or
12.40
GUEc,bin/AEFc,bin
0.000 kW
P
CK
P
0.022 kW
SB
6600 m
3
/h
kg CO
2 eq
2087.5
(100 years)
Symbol
Value
Unit
η
165.0 %
S,h
COPd or
2.85
GUEh,bin/AEFh,bin
COPd or
4.45
GUEh,bin/AEFh,bin
COPd or
4.80
GUEh,bin/AEFh,bin
COPd or
5.36
GUEh,bin/AEFh,bin
COPd or
2.50
GUEh,bin/AEFh,bin
COPd or
2.20
GUEh,bin/AEFh,bin
COPd or
x,x
GUEh,bin/AEFh,bin
TOL
-15 ℃
Supplementary heater
elbu
0.0 kW
0.022 kW
P
SB
7200 m
3
/h
x m3/h
kg CO2 eq
2087.5
(100 years)