Sanus LF228 Manual Del Usuario página 9

Ocultar thumbs Ver también para LF228:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
2
Mount the Wall Plate
Solid concrete or concrete block
2-1
Mark the wall
≥41 cm
(16 in.)
2-2
Drill pilot holes
2-3
Insert anchors and lag bolts
[26]
[26]
6901-002114 <03>
For assistance in determining wall plate location, see Height Finder at
sanus.com.
Level the wall plate [01] and mark the hole locations.
[01]
Drill pilot holes as illustrated.
Insert lag bolt anchors [26]. Then insert lag bolts [25] through the
washers [27], wall plate [01], and into the anchors.
lag bolt. To avoid potential injuries or property damage:
[27]
CAUTION:
Avoid potential injuries or property damage!
Mount the wall plate [01] directly onto the concrete surface.
Minimum solid concrete thickness: 203 mm (8 in.)
Minimum concrete block size: 203 x 203 x 406 mm (8 x 8 x 16 in.)
For all concrete applications, the arm must remain centered in
the wall plate (step 3). Keep this in mind when selecting the wall
plate location.
Minimum horizontal space between fasteners: 406 mm(16 in.).
CAUTION:
Avoid potential injuries or property damage! :
Pilot holes MUST be drilled to a depth of 89 mm (3.5 in.) using a
10 mm (3/8 in.) diameter drill bit.
Never drill into the mortar between blocks.
89 mm
(3.5 in.)
CAUTION:
Improper use could reduce the holding power of the
Be sure the anchors [26] seat fl ush with the concrete surface.
[01]
[25]
13 mm
10 mm
(1/2 in.)
(3/8 in.)
Tighten the lag bolts [25]
only until the washers [27]
are pulled fi rmly against
the wall plate [01].
DO NOT over-tighten the lag
bolts [25].
9
Tabla de contenido
loading

Tabla de contenido