Service
Cleaning
DANGER!
Switching off the device!
Turn the device off using the on/off
switch before you remove the plug from
the socket.
Cleaning
DANGER!
Instructions for Cleaning!
Use a soft, lint-free cloth. Never use liq-
uid
or
easily
(sprays, abrasives, polishes, alcohol,
etc.). Do not allow any moisture to reach
the interior of the device. Do not spray
the device with any cleaning fluids.
Wipe over the surfaces gently. Be care-
ful that you do not scratch the surfaces.
Cleaning the feed rollers
1 Switch the device off.
2 Press and hold the # key until the control lamp
POWER light up.
3 The scanner is now in cleaning mode.
4 Push the cleaning sheet into the document
feeder.
Notice
Instructions for Cleaning
Observe the direction of feed. The
white sponge must be on the upper
side.
Do not use any cleaning agents or
cleaning fluids. Doing so can perma-
nently damage the feed rollers.
flammable
cleansers
5 The sheet is automatically fed and the cleaning
process started. During cleaning, the control
lamps POWER and STATUS flash.
6 After cleaning is complete, the sheet is ejected
and the control lamp POWER goes out.
Notice
Cleaning sheet for the feed rollers
Store the cleaning sheet in a dust-
free location.
Calibrating the scanner
Calibrate the scanner if colors appear in areas
that should be white, or colors of the scanned im-
age and the original vary a lot. This allows you to
adjust and compensate for variations that can oc-
cur in the optical component over time by its na-
ture.
1 Clean the feed rollers and the scanner glass
first before calibrating the scanner.
2 Insert a memory card which is not read-only
into the appropriate card slot at the rear of the
device.
3 Press and hold the # key until the control lamp
for the device status is constantly on.
4 Place the calibrating sheet in the document
feeder with the arrows facing the feed rollers.
5 The sheet is automatically fed and the calibra-
tion process started.
Notice
Calibrating the scanner
Observe the direction of feed. If the
calibration sheet is inserted incor-
rectly, the calibration process cannot
be started.