DURAVIT DuraSystem WD5006 Manual De Uso página 55

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 109
Problem
Continuous flushing
Inadvertent flushing
LED on the actuator plate
flashes, no flush
Potential cause
Solenoid valve is installed
incorrectly
Solenoid valve is faulty
(remove the contact on the
solenoid valve: flushing
continues)
Electronics are defective
(remove the contact on the
solenoid valve: flushing
stops)
Hygiene flush is activated
Dynamic flush volume is
activated
Presence detection is
incorrectly set (detection
range is too large)
Cleaning function is active
Obstacle within the detec-
tion range, e.g. furniture
Presence detection is
incorrectly set (detection
range is too small)
Battery is discharged
Solution
>
Observe the flow direction
(arrow must point in the
flow direction)
>
Replace the solenoid valve
>
Replace the electronics
>
Deactivate the hygiene
flush
>
Deactivate the dynamic
flush volume
>
Adjust the presence detec-
tion range
>
Deactivate the cleaning
function
>
Remove the obstacle
>
Adjust the presence detec-
tion range
>
Activate the special mode
for small rooms
>
Insert a new battery