30. Place the generator (2) to the engine and install the
retainers (1).
31. Tighten the generator mounting retainers to 25 N∙m
(18 ft. lbs.).
32. Install the B+ cable (3) and retainer (2).
33. Tighten the B+ retainer to 13 N∙m (10 ft. lbs.).
34. Install the generator field connector (1).
35. Position the radiator fan module (1) in retaining clip.
36. Make sure clips are fully engaged.
37. Install the wiring harness loom across the upper radi
ator core support.
38. Connect the radiator fan electrical connector.
39. Install the upper radiator hose at radiator.
40. Fill the cooling system.
Mar 17, 2011
5