pico Technology PicoScope 4225A Guía De Seguridad página 54

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
Safety Guide
Current probes are marked with their maximum voltage rating, which applies when clamped over
an uninsulated conductor.
To prevent injury or death, do not use any current probe on an uninsulated conductor operating
outside the probe's marked voltage protection levels.
To prevent injury or death, do not fit a current probe over an energized, uninsulated hazardous live
conductor unless the probe is expressly marked as safe to do so by using the
de-energize uninsulated circuits before fitting probes marked with the
When measuring currents in uninsulated circuits connected directly to the mains supply, always
use probes with the appropriate CAT ratings.
To prevent injury or death, always follow the CAT rating of the probe and do not use a non CAT-
rated current probe to measure mains current.
Always use extreme caution when working around bare conductors or bus bars. Contact with
the conductor could result in electric shock. Always follow relevant industry-standard safety
procedures and use appropriate Personal Protective Equipment (PPE) where applicable. Safety
training is essential in these cases and should be separately gained.
All current probes have a maximum RMS current rating which may be derated depending on the
measurement frequency in accordance with the table below.
Probe maximum RMS current by frequency
Probe
400 Hz to
< 400 Hz
TA018
60 A
TA019
600 A
TA167 2000 A
200 A
TA189
30 A
TA234
30 A
TA388 2000 A
200 A
TA408
100 A
100 A
TA473
60 A
To avoid damage to the probe and inaccurate readings, do not use a current probe on a circuit
that exceeds the probe's maximum rated frequency or the maximum rated RMS current at the
measurement frequency
Failure to observe the above safety precautions may cause damage to the current probe leading to
an effective reduction in its safe voltage rating and CAT rating.
DO336-1
PicoScope 4225A and 4425A automotive oscilloscope and accessories
1 kHz to
10 kHz to
1 kHz
10 kHz
20 kHz
60 A
40 A
40 A
30 A
30 A
30 A
30 A
30 A
30 A
40 A
100 A
100 A
60 A
60 A
60 A
WARNING
WARNING
WARNING
Auto
20 kHz to
power-off
60 kHz
no
no
yes
30 A
yes
no
N/A
N/A
N/A
CAUTION
WARNING
symbol. Always
symbol
Power supply/battery Connection