0 9
DAILY MODE
In Daily mode the product will be active for
selected hours every day. Note that the daily mode
will start the same time following days as the first
cycle is started on day one.
Push silver button
to activate the
purifier
Push daily button
daily
effect
timer
to select daily
mode
Push to adjust
daily
effect
timer
effect
E N
12
Push timer to
8
select treatment
hours each day
daily
effect
timer
Treatment starts
automatically after
a few second.
NOTE - Push and hold timer to activate delay function.
After the delayed hours have passed, Daily mode will
start automatically. Daily mode will run every day until
another setting is selected or the machine is turned off.
1 0
MAINTENANCE
Ozoneair Purify only requires a small amount
of
maintenance, some
parts
need
regular
replacement for the machine to run properly and
ensure high quality purifying.
UV lamps
After approximately one year of continuous use or 5000 operating hours,
the UV lamps needs to be replaced as their power has decreased. The
"Replace UV" indicator will light up on the display when the UV lamps
needs to be replaced. Below, instructions regarding how to order and
safely change the UV lamps will follow.
SAFETY PRECAUTIONS UV LAMPS
• Always keep the UV lamps in the provided protective case or cover
until installation.
• Let the lamps cool at least 15 minutes before opening the lamp holders.
• Be careful not to touch the new UV lamps when placing them inside,
this will decrease the ability of the UV source.
• Use a cloth or cotton gloves as protection if needed.
• Do not stress the glass parts when tightening the electrical connections,
risk of breaking.
Remove/insert UV lamps
Make sure
the product is
disconnected from
power.
Open the two
hatches on the
bottom of the
product and loosen
the two screws.
Pull the lamp
holders straight
out from the
product.
Pull the lamp
straight out from
the base.
E N
13