Thermostatic Cartridge replacement/servicing
A. Close hot and cold supply valves located at either side of
the mixing valve body.
B. Attach the sleeve removal tool (supplied) to the cartridge
sleeve.
C. Use an adjustable wrench to turn the sleeve removal tool
counter-clockwise to remove the sleeve.
D. Remove the metal washer . Extract Cartridge from valve:
grasp stem with pliers and carefully pull thermostatic
cartridge straight out of socket. Take care not to damage
spline on stem.
E. Remove the stem extension using screwdriver and replace
the thermostatic cartridge.
F. Reinstall the stem extension and slide cartridge into valve
socket : THE NOTCH OF STEM EXTENSION SHOULD BE
IN LINE WITH THE NOTCH OF CARTRIDGE STEM.
G. Reinstall washer and sleeve.
H. See temperature calibration section for setting max
temperature.
I. Reinstall trim to valve.
Replacement/entretien de la valve-filtre
A. Couper l'alimentation avec un tournevis.
Entretien
Votre nouveau robinet est conçu pour fonctionner sans problème, des années durant. Nettoyez-le périodiquement avec un chiffon doux pour qu'il conserve la même apparence qu'à l'état neuf. Évitez
les nettoyants abrasifs, la laine d'acier et les produits chimiques forts puisqu'ils endommageront le fini et rendront votre garantie nulle.
gerberonline.com pour enregistrer votre produit aujourd'hui.
Mantenimiento
Su grifo nuevo está diseñado para brindar años de servicio sin problemas. Mantenga su apariencia nueva limpiándolo periódicamente con un paño suave. Evite limpiadores abrasivos, estropajo
de acero y químicos cáusticos porque deslustrarán el acabado y anularán la garantía.
Registro de la garantía:
por favor ingrese para gerberonline.com para registrar su producto en la actualidad.
Enregistrement de la garantie:
A.
B.
C.
D.
veuillez vous connecter sur