DSW3 Input FCC
Off= Enabled input
On= Disabled input.
DSW4 Input FCA
Off= Enabled input
On= Disabled input.
DSW5 Input FTC
Off= Enabled input
On= Disabled input.
DSW6 Input STOP
Off= Enabled input
On= Disabled input.
Programmable functions
The RI.10KI control unit is equipped with connector to communicate with the programming display.
If the display is not used, the control unit can be programmed as follows:
The functions for which it is possible to choose between a range of values can be preset by using
the programming push-button (PGM) together with the Dip-switches. The fixed values are indicated
with "(def.)".
To store the programmable functions in memory, move the Dip-switches as shown in the table, then
press the push-button PGM for at least 2 seconds. The light of the "PGM" LED, which normally
flashes, will be steady. When the LED switches off, then the programming has been successfully
carried out. At this point, the push-button can be released and the LED start flashing.
At completion of the programming procedure, move the Dip-switches to the normal posi-
tions.
This control unit performs the power circuit integrity test automatically. Should a fault be detected,
the unit stops and indicates the fault through two blinks of the PGM led in rapid succession.
The triggering of the thermal switch is considered a fault in the power circuit, and once the thermal
protection is reset, the control unit restarts automatically. If the control unit keeps on indicating a
faulty operation, even when the motor has cooled down, try to momentarily switch power off.
Checking the integrity of the power circuit
The control unit has the possibility of checking the integrity of the power circuit (TRIAC).
According to the factory setting, this function is disabled.
To check:
- Set the Dip-switches 1=ON and 8=ON
- Press PGM, the LED blinks twice briefly, then goes out.
With the control activated, in the event of a fault in the power circuit or of tripping of the protection,
the control unit does not perform any kind of command.
To deactivate checking:
- Set the Dip-switches 1=ON and 8=OFF
- Press PGM until the blinking LED goes out.
With the control deactivated, even in the event of a malfunction in the power circuit the control unit
still performs the command.