INSTALLATION – IMPORTANT NOTICE
The operational setting up of household appliances in their environment
is a delicate operation that, if not done correctly, can have serious
consequences for consumer safety.
Therefore, this work must be entrusted to a professional who can carry
it out in compliance with the technical standards in force.
However, if despite this recommendation, the consumer carries out
the installation themself, the Candy Group will not accept any
responsibility in case of technical failure of the product whether or
not it causes damage to goods and/or persons.
INSTALLATION – ELECTRICAL CONNECTION
«The installation receiving the appliance referred to must comply with the standard in
force in the installation country». The Candy Group does not accept any responsibility if
this provision is not complied with.
Caution:
• Before connecting, check the power supply voltage shown on the meter, the
circuit breaker setting, the fuse rating and the earth continuity of the installation.
• The electrical connection to the mains must use an earthed socket outlet, or
pass though an all-pole cutting device having a minimum contact opening dis-
tance of 3 mm.
If the appliance has a socket outlet, it must be installed so that the socket outlet is
accessible.
• The green/yellow protection wire must be linked to the earth terminals, of the
appliance on one side, and the installation on the other side.
• We cannot be held responsible for any incident or its consequences that may
arise during the use of an appliance not linked to the earth, or linked to an earth
whose continuity is defective.
• All work in relation to the power supply cable must be carried out by the after
sales service or someone with similar qualifications.
The hob is fitted with a power supply cable which allows it to be connected only to a
power supply of 220-240 V between phases or between phase and neutral.
• Connect to a 25 Amp socket. Before connecting it is compulsory to check :
. the power supply voltage shown on the electricity meter,
. the adjustment of the circuit breaker, and,
. the fuse rating 20 A (PVD 603/604/605) - 25 A (PVD 750).
40 -