Note: Place the excess cable on the apposite fairhead
(equipped with screw for tightening).
12. Join the two top sections of the flue to cover the truss so
that one of the slots on the sections is situated on the
same side of the control panel and the other on the
opposite side. Screw the two sections together with 8
screws (4 each side- see the plan diagram for joining the
two sections).
13. Fix the top flue assembly to the truss, near the ceiling,
with 2 screws (one each side).
Fig. 12
14. Couple the two lower sections of the flue to cover the
trellis using 6 screws (3 per side. See also the diagram
plan for coupling the two sections).
15. Insert the bottom section of the flue in its seat so that it
completely covers the motor compartment and electrical
connection box, then ensure it from inside the hood using
2 screws.
Fig. 13
16. Apply the 2 tabs (supplied) to cover the fixing points of the
bottom flue (CAUTION! THE BOTTOM FLUE TABS ARE
THE NARROWER AND SHALLOWER ONES).
The wider and deeper tabs are those used for the top flue,
and must be cut to size.
Turn the mains power on again at the central electrical panel
and check for correct hood operation.
Additional instructions for the montage
Installing the panel
(number and form of the panels can vary on the basis of the
model)
The panel is supplied dismounted.
Hook the panel onto the pins of the hood and fix with the
supplied latch S (the number varies on the basis of the model
- safety-fixing compulsory!).
Rotate the panels to cover the suction area and hook to the
pins, pressing with decision.
Check that the panel is blocked in position. Fig. 1
Description of the hood
Fig. 1
1. Control panel
2. Grease filter
3. Grease filter release handle
4. Halogen lamp
5. Vapour catcher
6. Telescopic chimney
7. Air outlet (used for filter version only)
8. Panel
Operation
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.
To select the functions of the hood just touch the commands.
Light key ON/OFF
Intensive speed selection key (suction
power) - duration 5 minutes - press again to
return to previous setting.
High-speed selection key (suction power).
Medium-speed selection key (suction power)
- when flashing it indicates the need to wash or
replace the carbon filter. This signal is normally
deactivated. Press keys 1 and 2 at the same
time to activate it. At first only key 1 will flash
and then both keys 1 and 2 to indicate
activation. Repeat the operation to deactivate
the signal. At first keys 1 and 2 will flash and
then only key 1 to indicate deactivation.
Low-speed selection key (suction power) –
when flashing it indicates the need to wash the
fats filter.
Motor key OFF (stand by) – excludes the
electronics – reset wash/replace filters signals.
MOTOR OFF
Press briefly to switch the motor off.
RESET FILTERS SIGNALS
After having carried out maintenance of the
filters, press the key for 3 seconds. Flashing led
1 (fats filter) or 2 (carbon filter) will stop
flashing.
EXCLUDING THE ELECTRONICS
Press the key for 3 seconds. The hood
command electronics will be excluded.
This function can be useful during the product
cleaning operations.
Just repeat the operation to reinsert the
electronics.
If the hood fails to operate correctly, briefly disconnect it from
the mains power supply for almost 5 sec. by pulling out the
plug. Then plug it in again and try once more before
contacting the Technical Assistance Service.