10
10E
10D
10C
10 FLUSHING & AERATOR CLEANING
After installation is complete, remove Aerator Housing (10A). Turn Valves (10B) on
and allow both hot and cold water to run for at least one minute each. While water is
running, check for leaks. To clean the aerator, disassemble Aerator Housing (10A) by
separating the Aerator Shell (10C), Basket (10D), and Washer (10E). Once parts have
been cleaned, reassemble by reversing steps.
11
11C
11J
11E
ENGLISH
10B
10A
11A
11B
11D
11F
11K
11G
11H
11 CARTRIDGE REPLACEMENT
Turn off water supplies and relieve pressure before working on your faucet. To
remove handle, remove Button (11A), unscrew Set Screw (11B) using a
and remove Lever (11C). Remove Handle Hub (11D) from Faucet Body (11E). Unscrew
Retainer Cap (11F) and Retainer Ring (11G). Carefully remove the Cartridge (11H) by
pulling it straight up and out. Reassemble valve by reversing steps.
This product comes with an extra Solid Colored Indicator (11J) that can be switched
with the Red and Blue Indicator (11K).
CAUTION: Maintenance
DISASSEMBLY
1.
Replacement parts may be available at the store where you purchased
your faucet.
2.
When replacement parts are not available, please write or call Price Pfister
Consumer Service.
Always turn off water and relieve pressure before working on your
3.
faucet.
NOTE: Trim Care
Cleaning Instructions:
For all Handles and decorative finishes, use only a soft damp cloth
to clean and shine. Use of polish, detergents, abrasive cleaners,
organic solvents or acid may cause damage. Use of other than
a soft damp cloth will nullify our warranty!
Special Trim:
Trim products which contain Porcelain or other similar substance
are not acceptable for public areas or Commercial use. Installation
of Said Trim is at Users Risk!
1–800–PFAUCET (1–800–732–8238)
For Toll-Free Pfaucet information call
1–800–PFAUCET (1–800–732–8238)
or visit www.pricepfister.com
• Installation Support
• Care and Warranty Information
4
3
" Hex wrench,
/
32