CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main fusebox before starting and during the installation.
This fixture is intended for installation in accordance with the National Electric Code (NEC) and Local code
specifications. Failure to adhere to these codes and instructions may result in serious injury and/or property damage
and will void the warranty. If you are not familiar with code requirements, installation by a certified electrician is
recommended.
1) WARNING: This fixture is not to be installed within 10 feet (3M) of a pool, spa or fountain.
2) According to the requirements of the National Electric Code (NEC), direct burial rated wire is to be buried a
minimum of 6" [152mm] beneath the surface of the ground.
NOTE: If additional Direct Burial wire is needed, contact your local Kichler
• 8 GA wire can be purchased in length of 250' (76 M),15503-BK.
• 10 GA wire can be purchased in length of 250' (76 M),15504-BK.
• 12 GA wire can be purchased in lengths of 100' (30 M),15501-BK; 250' (76 M), 15502-BK; 500' (152M),
15505-BK; and 1000' (304 M), 15506-BK.
3) Wiring connections must be made with approved/listed wire connection device(s) suitable for the application. Do
not exceed manufacturers' wiring combination specifications for size and quantity of conductors.
WHEN INSTALLING KICHLER LANDSCAPE LIGHTING (LINE VOLTAGE OR LOW VOLTAGE), CARE SHOULD BE
TAKEN TO KEEP CLEAR OF POTENTIALLY COMBUSTIBLE MATERIALS.
WHEN MAINTAINING THE FIXTURES, BE SURE TO REMOVE LEAVES, PINE NEEDLES, GRASS CLIPPINGS,
MULCH, OR ANY DEBRIS THAT HAS ACCUMULATED ON THE LIGHT BULB, LENS, OR BODY OF THE FIXTURE.
ASSEMBLY AND INSTALLATION
1) Determine desired location for mounting fixture.
2) At desired location, hammer stake into ground. To avoid damage to stake, place a board on top of stake while
hammering. If ground is hard and stake is difficult to install, make a crosscut in ground using a flat shovel.
3) Clear away area in ground at wireway slot in top of stake.
4) Lay 12V cable into wireway slot and screw fixture into stake. Aim fixture in desired direction and secure by tightening
locknut. If necessary, use wrench or pliers for final tightening of nut.
5) Adjust angle of accent light by loosening Phillips head screw.
6) Adjust angle of cowl by loosening thumb screw.
7) TURN OFF POWER.
8) Make wire connections using supplied wire connectors following instructions included, or using other approved wiring
connection method (not supplied).
TO CHANGE LIGHT OUTPUT SETTING:
NOTE: Fixure switches up in terms of lumen settings; it starts at "LEVEL 1" (1000 lumens). If this level is desired, no
•
adjustment is needed.
Locate the dimple at the top of the fixture. (This is called a lumen adjustment switch locator)
•
Hold magnet on lumen adjustment switch locator for 1.5 seconds to begin programming mode. Remove magnet.
•
Fixture will blink continuously 3x's at full brightness level and go dark for 2 seconds and then will illuminate at original
•
factory setting ("LEVEL 1", 1000 lumens).
To switch lumen settings, magnet must be reapplied to lumen adjustment switch locator for 1.5 seconds and magnet
•
must be removed for 1 second between switching.
NOTE: fixture blinks 1x for "LEVEL 1" (1000 lumens), 2x's for "LEVEL 2" (1200 lumens).
•
Once the fixture is set and magnet removed, it stays in programming mode for 2 minutes.
•
After 2 minutes, the memory is set.
•
To change the output brightenss, return to programming mode by holding magnet on magnetic locator for 1.5 seconds.
•
NOTE: Fixture reverts back to original factory setting when put back into programming mode.
•
NOTE: Once the desired setting is set, mark the level (1 or 2) with a marker on fixture under the cowl.
•
Wire Gauge/Power/Length Chart
Wire Gauge/Length (ft/m) per run
WATTS
(VA)
10
1860/567
1150/351
0 - 20
930/283
40
620/189
60
470/143
80
370/113
100
Consult Technical Support
>100
Fixture Load Chart
Lumen Level
2
1
NOTE: When sizing your transformer please use the highest VA you expect to use depending
on desired lumen level per fixture to prevent potentially overloading the transformer.
Best practice is to use VA/wattage buffer of 30% when sizing a transformer to account for fixture
lumen adjustments. (ie. 210 VA on 300VA transformer.)
IMPORTANT! PLEASE READ
SAFETY INSTRUCTIONS
READ THIS FIRST
KEEP THESE INSTRUCTIONS
landscape distributor.
®
CAUTION
12
14
16
730/223
450/137
580/177
370/113
230/70
390/119
240/73
150/46
290/88
180/55
110/34
230/70
140/43
90/27
VA (AC Power
WATTS (DC Power
Supplies)
Supplies)
23
18
14
19
For warranty information please visit: kichler.com/warranty
LUMEN ADJUSTMENT
SWITCH LOCATOR
Lumen Level Table (For 2700K/3000K/5000K)
LEVEL 1
*1000 Lm
LUMEN ADJUSTMENT
SWITCHING
SWITCH LOCATOR
MAGNET
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
This device may not cause harmful interference, and
1)
This device must accept any interference received, including interference
2)
that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
We're here to help
FIXTURE
PHILLIPS HEAD SCREW TO
ADJUST ANGLE OF FIXTURE
LOCKNUT
STAKE
SWITCHING
PROGRAMMING MODE
LEVEL 2
1200 Lm
* DENOTES FACTORY SETTING
PROGRAMMING MODE
FCC INFORMATION
there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which
•
the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
•
866-558-5706
Hrs: M-F 9am to 5pm EST
THUMB SCREW
TO ADJUST ANGLE
OF COWL OR TO
LOOSEN AND
REMOVE COWL
WIRE LEADS
MAGNET
ORIGINAL
LEVEL 1
LEVEL 2
IS-16160-US