Technical Parameters - Elko EP HRH-1 Manual De Instrucciones

Ocultar thumbs Ver también para HRH-1:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25

Technical parameters

Function:
Supply terminals:
Voltage range:
Power input:
Supply voltage tolerance:
Measuring circuit
Hysteresis (input - opening):
Voltage on electrode:
Current in probes:
Time reaction:
Max. cable capacity:
Time delay tD:
Time delay tH:
Accuracy
Setting accuracy (mech.):
Output
Number of contacts:
Current rating:
Breaking capacity:
Inrush current:
Switching voltage:
Mechanical life:
Electrical life (AC1):
Other information
Operating temperature:
Storage temperature:
Electrical strength:
Operating position:
Mounting:
Protection degree:
Overvoltage category:
Pollution degree:
2
Max. cable size (mm
):
Dimensions:
Weight:
Standards:
HRH-1
3
A1 - A2
AC 110 V, AC 230 V or AC/DC 24 V
galvanicaly separated (AC 50 - 60 Hz)
max. 4.5 VA
-15 %; +10 %
in an adjustable range 5 kΩ - 100 kΩ
max. AC 5 V
AC < 1 mA
max. 400 ms
4 nF
adjustable, 0.5 - 10 sec
adjustable, 0.5 - 10 sec
± 5 %
2x changeover / SPDT (AgNi / Silver Alloy)
16 A / AC1
4000 VA / AC1, 384 W / DC
30 A / < 3 s
250 V AC1 / 24 V DC
3x10
7
5
0.7x10
-20 °C to 55 °C (-4 °F to 131 °F)
-30 °C to 70 °C (-22 °F to 158 °F)
4 kV (supply - output)
any
DIN rail EN 60715
IP40 from front panel / IP20 terminals
III.
2
solid wire max. 1x 2.5, max. 2x 1.5 /
with sleeve max. 1x 1.5 (AWG 12)
90 x 52 x 65 mm (3.5˝ x 2˝ x 2.6˝)
9 oz (256 g) (110V, 230 V); 5.6 oz (158 g) (24 V)
EN 60255-6, EN 61010-1
Function
Two separate level switches
Un
probe D
LED D
OUT1- relay D
tD
probe H
LED H
OUT2- relay H
tH
Un
probe D
LED D
OUT1- relay D
tD
probe H
LED H
OUT2- relay H
tH
Two probes in single tank
Un
probe D
probe H
LED D
OUT1- relay D
LED H
OUT2- relay H
tH
Un
probe D
probe H
LED D
OUT1- relay D
tD
LED H
OUT2- relay H
tH
The relay, which is used to control the level liquids conductive (water, chemical solutions,
food, etc.).
In this principle, it goes on about the measurement of liquids by measuring probes. As the
measuring used signal is 5 V AC / 500 Hz. Using an AC signal prevents the the increasing
oxidation of probes and unwanted polarization and electrolysis liquid. During depending
on the DIP settings confi gurations, switches can control two independent levels or use a
combined function for one level (see diagram of functions).
The relay is equipped with regulation of the sensitivity to to liquid resistance. It's also
possible to eliminate some of the unwanted switching in the sensitivity settings according
to specifi c conditions (for example, pollution probe sediments, humidity, etc.). It's also
possible for each probe to set the delay in the range of 0.5 - 10 s, and using the DIP switch
type delay (when you turn the relay on and off , depending on application).
2 / 3
- when the tank is empty
relay D open, relay H is
closed
tD
tH
- when the tank is empty
both relays are switched
tD
tH
tD
tD
tH
tD
tH