e
2
STAGE
1.5) Heating rate 2 (RP2) 1 to 15° /min - FULL - STOP
Heat rise to reach the second stage. The principle is the same as for
heating rate 1, except that the programmed values may differ.
1.6) Temperature of the 2nd stage - 0 to 1200.C (see paragraph 3 above)
1.7) Hold time. 0 to 240 min (see paragraph 4 above)
e
3
STAGE
1.8) Heating rate 3 (RP3) - 1 to 15°C/ min - FULL - STOP
1.9) Temperature 0 to 1200° C
2.0) Hold time. 0 to 240 min
2.1) Final time-delay 0 to 240 min
This timer function sets a time delay before the firing cycle is stopped completely.
Once you have programmed your full cycle, you may program the furnace10 hold at the last
temperature for 0 to 240 min, in addition to the hold time.
This means that you can choose the time you need to perform your castings.
2)
PROGRAM NUMBER DISPLAY 0 TO 29 :
If the control station is on stand-by, the program number can be changed using the keys
The control station has a storage capacity of 30 programs.
Programs 0 through 19 are 3-stage programs.
Programs 20 through 29 are 6-stage programs.
. The program number cannot be changed while the furnace is in operation (the program number
blinks , key
3)
TEMPERATURE /TIME DISPLAY
This display gives you the value of the parameters while setting up the program
During the heating cycle, you can choose to display either:
- The temperature during the heat rise and the countdown during the hold periods,
- Or the temperature only.
ln that case, press the
A dot then appears at the far right of the display
or when the cycle has begun (
key.
control).
3
to indicate that you have chosen the temperature mode.
23
PROGRAMIX 25/50/100